EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Material–interface trade-offs in biomaterial-based femoral head reconstruction for osteonecrosis: A finite element comparison

Tianchen Zhang, Yuyang Zhai, Zilei Xia, Shanbin Zheng, Tianwei Xia, Chao Zhang, Yang Guo, Jirong Shen

Materials & Design · 2026-12 · 272 · 117346

DOI: 10.1016/j.matdes.2026.117346 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials & Design, 2026-12. Verfasst von Tianchen Zhang und 7 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early stability after femoral head reconstruction reflects implant stiffness, interface fixation, and load-transfer geometry, yet these effects are difficult to separate clinically. We compared four reconstructions in one computed tomography–derived femur with heterogeneous bone properties and a standardised weight-bearing lesion (∼35% of femoral-head volume). Heel strike (HS), mid-stance (MS), and toe-off (TO) were simulated for an isolated fibular strut, screw-augmented strut, porous tantalum rod, and porous β-tricalcium phosphate rod. The screw-augmented strut produced the lowest displacement (1.393–2.108 mm) and subchondral stress (92.3–125.3 MPa), whereas the isolated strut had the lowest mean micromotion (0.080 mm). The β-tricalcium phosphate rod had the lowest implant tensile stress (1.109–1.994 MPa) but the greatest displacement and micromotion. In the tantalum model, increasing interface friction from 0.2 to 0.5 reduced micromotion by 9.4–13.7%, while displacement and subchondral stress changed by < 0.2%. Scenario weighting favoured the screw-augmented strut for collapse resistance and the isolated strut for interface stability. Within this standardised model, performance reflected trade-offs among support, fixation, and material stress rather than stiffness alone. Experimental validation and patient-specific modelling remain necessary before clinical translation.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, T., Zhai, Y., Xia, Z., Zheng, S., Xia, T., Zhang, C., Guo, Y., & Shen, J. (2026). Material–interface trade-offs in biomaterial-based femoral head reconstruction for osteonecrosis: A finite element comparison. Materials & Design, 272, 117346. https://doi.org/10.1016/j.matdes.2026.117346

Vancouver

Zhang T, Zhai Y, Xia Z, Zheng S, Xia T, Zhang C, et al. Material–interface trade-offs in biomaterial-based femoral head reconstruction for osteonecrosis: A finite element comparison. Materials & Design. 2026;272:117346. doi:10.1016/j.matdes.2026.117346

BibTeX
@article{Zhang2026,
  author = {Zhang, Tianchen and Zhai, Yuyang and Xia, Zilei and Zheng, Shanbin and Xia, Tianwei and Zhang, Chao and Guo, Yang and Shen, Jirong},
  title = {Material–interface trade-offs in biomaterial-based femoral head reconstruction for osteonecrosis: A finite element comparison},
  journal = {Materials & Design},
  year = {2026},
  volume = {272},
  pages = {117346},
  doi = {10.1016/j.matdes.2026.117346}
}
Kostenlos starten →