Biomechanical evaluation of fixation techniques for isolated Letenneur Type I lateral Hoffa fractures: A cadaveric model
The Knee · 2026-10 · 62 · 104548
DOI: 10.1016/j.knee.2026.104548 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Knee, 2026-10. Verfasst von Çağatay Baltacı und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Ankara University Medical Faculty, Ankara, Turkey. Hauptthemen laut MEDLINE: Fracture Fixation, Internal, Femoral Fractures, Distal, Hoffa Fracture, Femoral Fractures. Die Arbeit nennt 18 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: The aim of this study was to biomechanically evaluate and compare five different fixation techniques for isolated Letenneur Type I lateral Hoffa fractures using a fresh-frozen cadaveric model under both static and dynamic axial loading conditions. METHODS: Twenty-five fresh-frozen distal femurs were homogeneously assigned to five groups based on fixation method: (A) two postero-anterior (PA) screws (6.5 mm), (B) two antero-posterior (AP) screws (6.5 mm), (C) two PA screws combined with a posterior 3.5-mm tubular plate, (D) one PA screw combined with a lateral 3.5-mm locking compression plate (LCP), and (E) two AP screws combined with a lateral horizontal 3.5-mm tubular plate. Specimens underwent dynamic loading (2500 cycles, five stages, 2 Hz) followed by static axial loading using a servo-hydraulic testing machine. The parameters evaluated included load at 3-mm displacement, ultimate load, stiffness, and photogrammetric displacement. RESULTS: Plate-augmented constructs demonstrated significantly superior biomechanical stability. Ultimate load was highest in Group C (1761.8 ± 299.5 N), followed by Group D (1564.4 ± 162.1 N) and Group E (1571.2 ± 420.8 N), all significantly greater than Groups A (902.4 ± 522.8 N) and B (1088.2 ± 323.1 N) (P < 0.01). Photogrammetric displacement was significantly lower in plate-augmented groups (Group C: 0.32 ± 0.24 mm; Group E: 0.59 ± 0.58 mm) (P < 0.05). No statistically significant differences were observed between screw-only constructs. CONCLUSIONS: Plate-augmented fixation provides superior biomechanical stability for isolated Letenneur Type I lateral Hoffa fractures. Lateral plating achieves comparable stability to posterior plating while avoiding the technical challenges. The comparable performance of screw configurations suggests that screw trajectory can be flexibly selected based on fracture morphology. These findings offer guidance for surgical planning and implant selection in the management of these complex fractures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics and Traumatology, Ankara University Medical Faculty, Ankara, Turkey.
- Department of Orthopedics and Traumatology, Ankara University Medical Faculty, Ankara, Turkey. Electronic address: kocaoglu@ankara.edu.tr.
- Department of Anatomy, Ankara University Medical Faculty, Ankara, Turkey.
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Ankara, Turkey.
Zitieren
APA
Baltacı, Ç., Baltacı, P. K., Kocaoğlu, H., Açar, H. İ., Uslan, Y., & Kalem, M. (2026). Biomechanical evaluation of fixation techniques for isolated Letenneur Type I lateral Hoffa fractures: A cadaveric model. The Knee, 62, 104548. https://doi.org/10.1016/j.knee.2026.104548
Vancouver
Baltacı Ç, Baltacı PK, Kocaoğlu H, Açar Hİ, Uslan Y, Kalem M. Biomechanical evaluation of fixation techniques for isolated Letenneur Type I lateral Hoffa fractures: A cadaveric model. The Knee. 2026;62:104548. doi:10.1016/j.knee.2026.104548
BibTeX
@article{Baltac2026,
author = {Baltacı, Çağatay and Baltacı, Peri Kından and Kocaoğlu, Hakan and Açar, Halil İbrahim and Uslan, Yunus and Kalem, Mahmut},
title = {Biomechanical evaluation of fixation techniques for isolated Letenneur Type I lateral Hoffa fractures: A cadaveric model},
journal = {The Knee},
year = {2026},
volume = {62},
pages = {104548},
doi = {10.1016/j.knee.2026.104548}
}
EUVIMED