EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A clinical applicable study on lower limb segmentation from CT images for total knee arthroplasty

Renyang Gu, Wenjia Bai, Shuqiao Xie, Pierluigi Cuomo, Gareth G Jones, Anthony M J Bull

The Knee · 2026-10 · 62 · 104526

DOI: 10.1016/j.knee.2026.104526 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Knee, 2026-10. Verfasst von Renyang Gu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Imperial College London, London W12 0BZ, United Kingdom. Electronic address: rgu@ic.ac.uk. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tomography, X-Ray Computed, Femur, Tibia. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innovate UK.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Segmentation of lower limb bones is essential for accurate preoperative planning in total knee arthroplasty (TKA), yet fully annotated CT datasets are rarely available in clinical practice. This study evaluated whether a partially supervised deep learning framework can leverage incompletely annotated CT data to generate anatomically accurate femur and tibia segmentations suitable for TKA planning. METHOD: A 3D nnU-Net model was trained using 205 healthy full-leg CT scans with mixed annotation completeness, including 17 fully annotated cases and partially labelled femur or tibia in the remaining scans. Performance was evaluated on an internal healthy dataset (n = 40), a cadaveric dataset (n = 15), and an osteoarthritis (OA) dataset acquired for robotic TKA planning (n = 10). Accuracy was assessed using Dice similarity coefficient (DSC), Hausdorff distance (HD), HD95, and root-mean-square surface distance (RMSE). Clinical relevance was evaluated using landmark localisation errors and joint alignment measurements (mLDFA and mPTA). RESULTS: On the cadaveric dataset, mean DSC values were 96.53% (femur) and 97.41% (tibia), with RMSE < 1 mm. On the OA dataset, mean DSC remained approximately 96.5% with HD95 < 1.7 mm across acquisition windows. Alignment measurements derived from automatic and manual segmentations showed small differences (mLDFA: 86.81° vs 87.02°, p = 0.11; mPTA: 86.74° vs 87.29°, p = 0.08), with no statistically significant differences observed. CONCLUSION: Partially supervised training enables accurate lower limb segmentation from incompletely annotated CT datasets and preserves clinically relevant alignment measurements required for TKA planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeTomography, X-Ray ComputedFemurTibiaOsteoarthritis, KneeHumansCadaverImaging, Three-DimensionalDeep LearningFemaleMale

Stichwörter der Autor:innen

CT segmentationDeep learningJoint alignmentKnee osteoarthritisSurgical planning

Autor:innen und Institutionen

  • Department of Bioengineering, Imperial College London, London W12 0BZ, United Kingdom. Electronic address: rgu@ic.ac.uk.
  • Department of Computing, Imperial College London, London SW7 2AZ, United Kingdom; Department of Brain Sciences, Imperial College London, London W12 0NN, United Kingdom.
  • Smart Surgical Solutions Ltd, London W12 0HT, United Kingdom.
  • Department of Bioengineering, Imperial College London, London W12 0BZ, United Kingdom.
  • Department of Surgery & Cancer, Imperial College London, London W12 0BZ, United Kingdom.

Förderung

  • Innovate UK

Zitieren

APA

Gu, R., Bai, W., Xie, S., Cuomo, P., Jones, G. G., & Bull, A. M. J. (2026). A clinical applicable study on lower limb segmentation from CT images for total knee arthroplasty. The Knee, 62, 104526. https://doi.org/10.1016/j.knee.2026.104526

Vancouver

Gu R, Bai W, Xie S, Cuomo P, Jones GG, Bull AMJ. A clinical applicable study on lower limb segmentation from CT images for total knee arthroplasty. The Knee. 2026;62:104526. doi:10.1016/j.knee.2026.104526

BibTeX
@article{Gu2026,
  author = {Gu, Renyang and Bai, Wenjia and Xie, Shuqiao and Cuomo, Pierluigi and Jones, Gareth G and Bull, Anthony M J},
  title = {A clinical applicable study on lower limb segmentation from CT images for total knee arthroplasty},
  journal = {The Knee},
  year = {2026},
  volume = {62},
  pages = {104526},
  doi = {10.1016/j.knee.2026.104526}
}
Kostenlos starten →