A newly developed patient-specific instrumentation system achieves consistent alignment accuracy in varising knee osteotomy
The Knee · 2026-06 · 60 · 104414
DOI: 10.1016/j.knee.2026.104414 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Knee, 2026-06. Verfasst von Takaaki Hiranaka und 6 weiteren Autor:innen. Beteiligte Einrichtung: Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia; Department of Orthopaedic Surgery, Section of Medicine…. Hauptthemen laut MEDLINE: Osteotomy, Knee Joint, Osteoarthritis, Knee, Surgery, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND Patient-specific instrumentation (PSI) has been introduced to improve the accuracy of varising knee osteotomy. This study aimed to evaluate the correction accuracy of a newly developed PSI system for varising knee osteotomy, including medial closing-wedge distal femoral osteotomy (MCWDFO), lateral opening-wedge distal femoral osteotomy (LOWDFO), and medial closing-wedge high tibial osteotomy (MCWHTO). METHODS Twenty-three patients with valgus knee alignment who underwent varus osteotomy using the new PSI system were retrospectively analysed (MCWDFO, n = 10; LOWDFO, n = 7; MCWHTO, n = 6). The overall error was defined as the difference between the planned and achieved hip-knee-ankle angles (HKAs) at 6 months postoperatively (ΔHKA), reflecting the accuracy of overall lower limb alignment correction. Positive values indicated overcorrection, and negative values indicated undercorrection. RESULTS Across all procedures, the mean planned and achieved HKA were 178.9° ± 0.7° and 179.3° ± 0.7°, respectively, resulting in a mean overall error of -0.4° ± 1.7° (range, -4.5° to 2.5°). The mean overall error was -1.0° ± 1.7° for MCWDFO, -0.5° ± 1.6° for LOWDFO, and 0.6° ± 1.1° for MCWHTO, with no significant difference among techniques (P > 0.05). No major complications, including hinge fracture or delayed union, were observed. CONCLUSIONS The newly developed PSI workflow achieved high correction accuracy and demonstrated consistent performance across various femoral and tibial osteotomy techniques for valgus correction. These findings indicate that the system provides a reliable and safe approach for achieving precise alignment correction in varus knee surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia; Department of Orthopaedic Surgery, Section of Medicine, Division of Medicine, Dentistry and Pharmaceutical Sciences, Graduat…
- Medical School, Division of Surgery, University of Western Australia, Perth, Western Australia, Australia; Orthopaedic Research Foundation of Western Australia, Perth, Western Australia, Australia; Fiona Stanley Fremant…
- Orthopaedic Research Institute of Queensland, Townsville, Australia.
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia.
- Orthopaedic Research Foundation of Western Australia, Perth, Western Australia, Australia; Fiona Stanley Fremantle Hospitals Group, South Metropolitan Health Service, Perth, Western Australia, Australia.
Zitieren
APA
Hiranaka, T., D'Alessandro, P., McEwen, P., Fritsch, B., Coward, J., Grasso, S., & Parker, D. (2026). A newly developed patient-specific instrumentation system achieves consistent alignment accuracy in varising knee osteotomy. The Knee, 60, 104414. https://doi.org/10.1016/j.knee.2026.104414
Vancouver
Hiranaka T, D'Alessandro P, McEwen P, Fritsch B, Coward J, Grasso S, et al. A newly developed patient-specific instrumentation system achieves consistent alignment accuracy in varising knee osteotomy. The Knee. 2026;60:104414. doi:10.1016/j.knee.2026.104414
BibTeX
@article{Hiranaka2026,
author = {Hiranaka, Takaaki and D'Alessandro, Peter and McEwen, Peter and Fritsch, Brett and Coward, Jonathan and Grasso, Samuel and Parker, David},
title = {A newly developed patient-specific instrumentation system achieves consistent alignment accuracy in varising knee osteotomy},
journal = {The Knee},
year = {2026},
volume = {60},
pages = {104414},
doi = {10.1016/j.knee.2026.104414}
}
EUVIMED