Imageless handheld robotic-assisted total knee arthroplasty showed better clinical outcomes than conventional total knee arthroplasty: A randomized controlled trial with preliminary results at 1-year follow up
The Knee · 2025
DOI: 10.1016/j.knee.2025.05.028 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift The Knee, 2025. Verfasst von Peter Bollars und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sint Trudo Hospital, Sint Truiden, Belgium. Electronic address: Peter.Bollars@stzh.be. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Osteoarthritis, Knee. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Smith & Nephew, Robotics, Orthopaedics, Trauma & Extremities, Smith and Nephew.
Abstract (Originalsprache)
BACKGROUND: Robotic-assisted total knee arthroplasty (RATKA) has been shown to achieve more accurate functional implant alignment than conventional instrumented TKA (CTKA). The aim of this randomized controlled trial was to assess differences in operative, clinical and functional outcome of RATKA compared with CTKA. METHODS: A total of 180 patients with osteoarthritis were included and randomized. Preoperative and 3- and 12-months postoperative patient-reported outcome measures (PROMs) and rate of serious adverse events (SAEs), requirement for ligament releases and implant sizes were compared. RESULTS: The preoperative baseline variables were not statistically different between RATKA and CTKA groups thus they were well matched. At 12 months follow up, RATKA had significantly better Oxford Knee Score (42.4 ± 5.4 vs. 38.7 ± 7.2, P < 0.001), KSSfunction (81.2 ± 12.3 vs. 72.7 ± 15.1, P < 0.001), KSSsatisfaction (34.9 ± 5.2 vs. 31.2 ± 7.9, P < 0.001), EQ5Dindex (0.883 ± 0.141 vs. 0.833 ± 0.144, P < 0.001), VAS painday (10.5 ± 12.5 vs. 21.5 ± 19.4, P < 0.001), and VAS painnight (8.1 ± 11.3 vs. 18.9 ± 19.5, P = 0.029), Patient satisfaction (93.2 ± 8.3 vs. 79.8 ± 20.3, P < 0.001) and FJS-12 (73.2 ± 23.3 vs. 53.6 ± 29.0, P < 0.001) as compared with the CTKA group. The proportion of patients in the RATKA group requiring ligament release was lower (six (7%) vs. 45 (50%), P < 0.001) and those requiring a polyethylene thickness ≤ 10 (55 (62%) vs. 36 (40%), P < 0.004). There was no difference in the rate of SAEs between the two groups. CONCLUSION: This randomized controlled trial found significantly higher PROMs in patients undergoing RATKA with no difference in SAEs as compared with CTKA. RATKA technology also showed reduced requirement for ligament release and smaller polyethylene sizes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sint Trudo Hospital, Sint Truiden, Belgium. Electronic address: Peter.Bollars@stzh.be.
- Imperial College Healthcare NHS Trust, London, UK; The Cleveland Clinic, London, UK.
- Orthocure Medical Center, Dubai, United Arab Emirates.
- Pius Hospital, Oldenburg, Germany.
- Heilig Hart Hospital, Lier, Belgium.
- Sint Trudo Hospital, Sint Truiden, Belgium.
Förderung
- Smith & Nephew, Robotics, Orthopaedics, Trauma & Extremities
- Smith and Nephew
Zitieren
APA
Bollars, P., Nathwani, D., Albelooshi, A., Ettinger, M., Verheyden, F., Mievis, J., Meshram, P., & Schotanus, M. (2025). Imageless handheld robotic-assisted total knee arthroplasty showed better clinical outcomes than conventional total knee arthroplasty: A randomized controlled trial with preliminary results at 1-year follow up. The Knee. https://doi.org/10.1016/j.knee.2025.05.028
Vancouver
Bollars P, Nathwani D, Albelooshi A, Ettinger M, Verheyden F, Mievis J, et al. Imageless handheld robotic-assisted total knee arthroplasty showed better clinical outcomes than conventional total knee arthroplasty: A randomized controlled trial with preliminary results at 1-year follow up. The Knee. 2025. doi:10.1016/j.knee.2025.05.028
BibTeX
@article{Bollars2025,
author = {Bollars, Peter and Nathwani, Dinesh and Albelooshi, Ali and Ettinger, Max and Verheyden, Frank and Mievis, Jan and Meshram, Prashant and Schotanus, Martijn},
title = {Imageless handheld robotic-assisted total knee arthroplasty showed better clinical outcomes than conventional total knee arthroplasty: A randomized controlled trial with preliminary results at 1-year follow up},
journal = {The Knee},
year = {2025},
doi = {10.1016/j.knee.2025.05.028}
}
EUVIMED