EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An AI-based system for fully automated knee alignment assessment in standard AP knee radiographs

Dominic Cullen, Peter Thompson, David Johnson, Claudia Lindner

The Knee · 2025-06 · 54 · 99-110

DOI: 10.1016/j.knee.2025.02.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Knee, 2025-06. Verfasst von Dominic Cullen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Informatics, Imaging and Data Sciences, School of Health Sciences, The University of Manchester, United Kingdom; Northern Care Alliance N…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Joint, Machine Learning, Osteoarthritis, Knee. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Royal Society.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Accurate assessment of knee alignment in pre- and post-operative radiographs is crucial for knee arthroplasty planning and evaluation. Current methods rely on manual alignment assessment, which is time-consuming and error-prone. This study proposes a machine learning-based approach to fully automatically measure anatomical varus/valgus alignment in standard anteroposterior (AP) knee radiographs. METHODS: We collected a training dataset of 566 pre-operative and 457 one-year post-operative AP knee radiographs from total knee arthroplasty patients, along with a separate test set of 376 patients. The distal femur and proximal tibia/fibula were manually outlined using points to capture the knee joint. The outlines were used to develop an automatic system to locate the points. The anatomical femorotibial angle was calculated using the points, with varus/valgus defined as negative/positive deviations from zero. Fifty test images were clinically measured on two occasions by an orthopaedic surgeon. Agreement between points-based manual, automatic, and clinical measurements was assessed using intra-class correlation coefficient (ICC), mean absolute difference (MAD) and Bland-Altman analysis. RESULTS: The agreement between automatic and manual measurements was excellent pre-/post-operatively with ICC 0.98/0.96 and MAD 0.8°/0.7°. The agreement between automatic and clinical measurements was excellent pre-operatively (ICC: 0.97; MAD: 1.2°) but lacked performance post-operatively (ICC: 0.78; MAD: 1.5°). The clinical intra-observer agreement was excellent pre-/post-operatively with ICC 0.99/0.95 and MAD 0.9°/0.8°. CONCLUSION: The developed system demonstrates high reliability in automatically measuring varus/valgus alignment pre- and post-operatively, and shows excellent agreement with clinical measurements pre-operatively. It provides a promising approach for automating the measurement of anatomical alignment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee JointMachine LearningOsteoarthritis, KneeBone MalalignmentHumansFemaleMaleAgedMiddle AgedRadiography

Stichwörter der Autor:innen

Clinical decision support systemKnee osteoarthritisMachine learningTotal knee arthroplastyVarus/valgus

Autor:innen und Institutionen

  • Division of Informatics, Imaging and Data Sciences, School of Health Sciences, The University of Manchester, United Kingdom; Northern Care Alliance NHS Foundation Trust, Salford, United Kingdom.
  • Division of Informatics, Imaging and Data Sciences, School of Health Sciences, The University of Manchester, United Kingdom.
  • Department of Trauma and Orthopaedics, Stockport NHS Foundation Trust, Stepping Hill Hospital, Stockport, United Kingdom; School of Health and Society, University of Salford, United Kingdom; School of Biological Science…
  • Division of Informatics, Imaging and Data Sciences, School of Health Sciences, The University of Manchester, United Kingdom. Electronic address: claudia.lindner@manchester.ac.uk.

Förderung

  • Wellcome Trust
  • Royal Society

Zitieren

APA

Cullen, D., Thompson, P., Johnson, D., & Lindner, C. (2025). An AI-based system for fully automated knee alignment assessment in standard AP knee radiographs. The Knee, 54, 99-110. https://doi.org/10.1016/j.knee.2025.02.013

Vancouver

Cullen D, Thompson P, Johnson D, Lindner C. An AI-based system for fully automated knee alignment assessment in standard AP knee radiographs. The Knee. 2025;54:99-110. doi:10.1016/j.knee.2025.02.013

BibTeX
@article{Cullen2025,
  author = {Cullen, Dominic and Thompson, Peter and Johnson, David and Lindner, Claudia},
  title = {An AI-based system for fully automated knee alignment assessment in standard AP knee radiographs},
  journal = {The Knee},
  year = {2025},
  volume = {54},
  pages = {99--110},
  doi = {10.1016/j.knee.2025.02.013}
}
Kostenlos starten →