Improvement of rotational arc during deep flexion range of a novel designed polyethylene insert for posterior-stabilised total knee arthroplasty
The Knee · 2024
DOI: 10.1016/j.knee.2023.11.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Knee, 2024. Verfasst von Hideki Ueyama und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Osaka Rosai Hospital, Osaka, Japan. Electronic address: ueyama.b@gmail.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: One of the remaining issues in total knee arthroplasty (TKA) is achieving sufficient rotational arc during deep flexion range of the knee for specific postures such as the 'seiza' or cross-legged sitting. This study aimed to evaluate whether there was a change in the actual in vivo rotational arc during deep flexion range before and after a design change of polyethylene (PE) inserts. METHODS: In 50 posterior-stabilised TKA cases, knee kinematics, including rotational movement, were measured intraoperatively using an image-free navigation system to compare a newly designed PE insert with reduced the posterior lip with a conventional PE insert. Femoral-tibial rotational angles at 30°, 45°, 60°, 90°, 120°, and 130° knee flexion were evaluated. Varus/valgus instability, knee range of motion, and femoral rollback were also measured. Obtained parameters were compared between new and conventional PE inserts. The independent factors associated with rotational arc during deep flexion range (120° and 130° knee flexion) were analysed using multivariate analysis. RESULTS: The newly designed PE insert demonstrated a significant increase in the rotational arc at 120° (22.9 ± 8.7° vs. 30.1 ± 11.9°, P < 0.001) and 130° (24.3 ± 9.5° vs. 32.5 ± 12.4°, P < 0.001) knee flexion compared with that with the conventionally designed posterior-stabilised insert. Multivariate analysis demonstrated that using the newly designed PE insert was an independent predictor of improved rotational arc during deep flexion range: regression coefficient was 11.2 (95% confidence interval 7.1-15.3, P < 0.001). CONCLUSION: The design change, which reduced the posterior lip of the PE insert, contributed to improved rotational arc in 120° and 130° deep flexion ranges.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Osaka Rosai Hospital, Osaka, Japan. Electronic address: ueyama.b@gmail.com.
- Department of Orthopaedic Surgery, Hanwa Memorial Hospital, Osaka, Japan.
- Department of Orthopaedic Surgery, Osaka Rosai Hospital, Osaka, Japan.
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine Osaka, Japan.
Zitieren
APA
Ueyama, H., Nakagawa, S., Fukunaga, K., Koyanagi, J., Takemura, S., Nakamura, S., Yamamura, M., & Minoda, Y. (2024). Improvement of rotational arc during deep flexion range of a novel designed polyethylene insert for posterior-stabilised total knee arthroplasty. The Knee. https://doi.org/10.1016/j.knee.2023.11.007
Vancouver
Ueyama H, Nakagawa S, Fukunaga K, Koyanagi J, Takemura S, Nakamura S, et al. Improvement of rotational arc during deep flexion range of a novel designed polyethylene insert for posterior-stabilised total knee arthroplasty. The Knee. 2024. doi:10.1016/j.knee.2023.11.007
BibTeX
@article{Ueyama2024,
author = {Ueyama, Hideki and Nakagawa, Shigeru and Fukunaga, Kenji and Koyanagi, Junichiro and Takemura, Susumu and Nakamura, Suguru and Yamamura, Mitsuyoshi and Minoda, Yukihide},
title = {Improvement of rotational arc during deep flexion range of a novel designed polyethylene insert for posterior-stabilised total knee arthroplasty},
journal = {The Knee},
year = {2024},
doi = {10.1016/j.knee.2023.11.007}
}
EUVIMED