Uncemented trabecular metal high-flex posterior-stabilized monoblock total knee arthroplasty in patients aged 60 years or younger
The Knee · 2024
DOI: 10.1016/j.knee.2023.11.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Knee, 2024. Verfasst von Radoslaw Wojtowicz und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical and Perioperative Sciences - Orthopedics, Umeå University, Umeå, Sweden. Electronic address: radoslaw.wojtowicz@regionvasterbo…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Osteoarthritis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Uncemented trabecular metal (TM) monoblock tibial components in total knee arthroplasty (TKA) have shown excellent clinical results for up to 10 years. However, these studies were performed in highly specialized units, with few surgeons and often excluding knees with secondary osteoarthritis (OA), severe malalignments and previous surgery. The purpose of this study was to investigate implant survivorship and clinical and radiological outcome of the uncemented TM high-flex posterior stabilized (PS) monoblock tibial component in routine clinical practice. METHODS: A retrospective study of 339 knees (282 patients) operated with the implant in routine clinical practice at two hospitals on patients aged 60 years or younger between 2007 and 2015. The operations were performed by 12 surgeons and there were no specific contraindications for use of the implant. Follow up ended in 2020. The status of the implant of deceased patients at death and those not attending follow up was checked with the Swedish Knee Arthroplasty Register. Clinical follow up consisted of clinical investigation, PROMs, and knee X-ray. RESULTS: Follow up was mean (range) 8.5 (5-13.8) years, and the 8-year survival rate was 0.98 (standard error 0.007). Five patients five knees) were deceased, five knees were revised (none due to aseptic loosening), and 16 patients did not attend the clinical follow up. Forty-four percent of the knees had secondary OA and 45% had had previous operations. 93% were satisfied or very satisfied with the operation and forgotten joint score (FJS) was median (interquartile range) 81 (44-94). Radiographic analysis revealed bone in close contact with the tibial tray and pegs in most cases, and in only 2% of the knees were potential radiolucent lines found. CONCLUSION: The results indicate that this uncemented implant performs excellently in routine clinical practice and also in younger patients with secondary OA or previous knee operations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgical and Perioperative Sciences - Orthopedics, Umeå University, Umeå, Sweden. Electronic address: radoslaw.wojtowicz@regionvasterbotten.se.
- Department of Surgical and Perioperative Sciences - Orthopedics, Umeå University, Umeå, Sweden.
- Department of Orthopedics, Falun General Hospital, Falun, Sweden.
Zitieren
APA
Wojtowicz, R., Otten, V., Henricson, A., Crnalic, S., & Nilsson, K. G. (2024). Uncemented trabecular metal high-flex posterior-stabilized monoblock total knee arthroplasty in patients aged 60 years or younger. The Knee. https://doi.org/10.1016/j.knee.2023.11.006
Vancouver
Wojtowicz R, Otten V, Henricson A, Crnalic S, Nilsson KG. Uncemented trabecular metal high-flex posterior-stabilized monoblock total knee arthroplasty in patients aged 60 years or younger. The Knee. 2024. doi:10.1016/j.knee.2023.11.006