Migrating peritoneal dialysis catheter into an inguinal hernia
Kidney International · 2026-08 · 110 (2) · 492-493
DOI: 10.1016/j.kint.2025.12.035 ↗Kurz gefasst
Fallbericht in der Zeitschrift Kidney International, 2026-08. Verfasst von Corey Toye und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada. Electronic address: ctoye043@uottawa.ca. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bayer Canada, Canadian Society of Nephrology.
Abstract (Originalsprache)
An 86-year-old man who had been stable on continuous cycling peritoneal dialysis for 2 years was seen in the clinic for sudden catheter flow dysfunction. His medical history included kidney disease from ischemic nephropathy, chronic obstructive pulmonary disease, hypertension, and prior bilateral direct inguinal hernia repairs. His catheter dysfunction began after a severe cough during an upper respiratory tract infection and was first identified through lost dwell times and repeated drainage alarms in his cycler treatment data.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Nephrology, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada. Electronic address: ctoye043@uottawa.ca.
- Division of Nephrology, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
- Division of Nephrology, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada; Division of Nephrology, Ottawa Hospital Research Institute, Ottawa, Ontario, Canada.
Förderung
- Bayer Canada
- Canadian Society of Nephrology
Zitieren
APA
Toye, C., Brown, P. A., & Canney, M. (2026). Migrating peritoneal dialysis catheter into an inguinal hernia. Kidney International, 110(2), 492-493. https://doi.org/10.1016/j.kint.2025.12.035
Vancouver
Toye C, Brown PA, Canney M. Migrating peritoneal dialysis catheter into an inguinal hernia. Kidney International. 2026;110(2):492-493. doi:10.1016/j.kint.2025.12.035
BibTeX
@article{Toye2026,
author = {Toye, Corey and Brown, Pierre Antoine and Canney, Mark},
title = {Migrating peritoneal dialysis catheter into an inguinal hernia},
journal = {Kidney International},
year = {2026},
volume = {110},
number = {2},
pages = {492--493},
doi = {10.1016/j.kint.2025.12.035}
}