EUVIMEDEUVIMED entdecken
Klinische Studie (Phase II)VergleichsstudieMultizentrische StudieValidierungsstudieOpen Access · CC BY-NC-ND 4.0

Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102)

Richard B Dorshow, Martin P Debreczeny, Stuart L Goldstein, Jeng-Jong Shieh

Kidney International · 2024-10 · 106 (4) · 679-687

DOI: 10.1016/j.kint.2024.06.012 ↗

Kurz gefasst

Klinische Studie (Phase II) in der Zeitschrift Kidney International, 2024-10. Verfasst von Richard B Dorshow und 3 weiteren Autor:innen. Beteiligte Einrichtung: MediBeacon Inc., St. Louis, Missouri, USA. Electronic address: rbdorshow@medibeacon.com. Hauptthemen laut MEDLINE: Fluorescent Dyes, Glomerular Filtration Rate, Iohexol, Renal Insufficiency, Chronic. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The fluorescent compound relmapirazin has been rationally designed for use in point-of-care measurement of glomerular filtration rate (GFR), with attributes including negligible protein binding, negligible metabolites in vivo, negligible tubular secretion, and excellent chemical and photo stability. Twenty-four nonclinical assays were performed in accordance with FDA requirements yielding negligible toxicology concerns. Here, a clinical study was performed to validate relmapirazin as a GFR tracer in patients by comparison to iohexol. This was evaluated in 120 adults at three clinical sites with eGFR values ranging from normal to Stage 4 chronic kidney disease. Relmapirazin and iohexol were administered intravenously in consecutive boluses to each subject and serial blood samples obtained over the subsequent 12 hours. Plasma concentrations were measured and the corresponding plasma GFR for each agent was determined using a standard two-compartment pharmacokinetic assessment. Urine from each subject was collected for the entire 12-hour study period to measure the amount of administered dose appearing in the urine. A near perfect linear regression correlation was observed between the GFRs measured by these two tracers (r2=0.99). Bland-Altman analysis confirmed agreement between these two measures of GFR (limits of agreement -7.0 to +5.6 mL/min; mean of -0.7 mL/min). The GFR determined by relmapirazin was independent of GFR stratification by chronic kidney disease stage, and importantly by race. The percent of the administered relmapirazin dose recovered in the urine was greater than or equal to that of iohexol with no reported severe adverse events. Thus, relmapirazin may be used as a GFR tracer agent in humans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesGlomerular Filtration RateIohexolRenal Insufficiency, ChronicAdultAgedFemaleHumansMaleMiddle AgedYoung AdultContrast MediaKidneyReproducibility of Results

Stichwörter der Autor:innen

MB-102clinical studyfluorescenceglomerular filtration rateiohexolrelmapirazin

Substanzen

Contrast MediaFluorescent DyesIohexol

Autor:innen und Institutionen

  • MediBeacon Inc., St. Louis, Missouri, USA. Electronic address: rbdorshow@medibeacon.com.
  • MediBeacon Inc., St. Louis, Missouri, USA.

Zitieren

APA

Dorshow, R. B., Debreczeny, M. P., Goldstein, S. L., & Shieh, J. J. (2024). Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102). Kidney International, 106(4), 679-687. https://doi.org/10.1016/j.kint.2024.06.012

Vancouver

Dorshow RB, Debreczeny MP, Goldstein SL, Shieh JJ. Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102). Kidney International. 2024;106(4):679-687. doi:10.1016/j.kint.2024.06.012

BibTeX
@article{Dorshow2024,
  author = {Dorshow, Richard B and Debreczeny, Martin P and Goldstein, Stuart L and Shieh, Jeng-Jong},
  title = {Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102)},
  journal = {Kidney International},
  year = {2024},
  volume = {106},
  number = {4},
  pages = {679--687},
  doi = {10.1016/j.kint.2024.06.012}
}
Kostenlos starten →