Anatomic feasibility of off-the-shelf fenestrated endovascular aneurysm repair devices: An anatomic study
Journal of Vascular Surgery · 2026
DOI: 10.1016/j.jvs.2026.05.038 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Vascular Surgery, 2026. Verfasst von Amun Hofmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular and Endovascular Surgery, Klinik Ottakring, Vienna, Austria. Electronic address: ah.reply@outlook.com. Hauptthemen laut MEDLINE: Endovascular Aneurysm Repair, Aortic Aneurysm, Abdominal, Blood Vessel Prosthesis, Stents. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVE: Fenestrated endovascular aneurysm repair enables treatment of complex aortic aneurysms involving visceral branches but is limited by patient-specific anatomical variability. Off-the-shelf (OTS) devices may reduce manufacturing delay; however, their feasibility depends on anatomic compatibility across populations. DESIGN: A large multicenter dataset was analyzed to evaluate the anatomic feasibility of standardized OTS fenestrated stent-graft configurations for juxtarenal and pararenal abdominal aortic aneurysms in this retrospective anatomic study. METHODS: Computed tomography angiography data from a sample of 8238 patients evaluated for fenestrated endovascular aneurysm repair between January 2018 and December 2023 were analyzed. Measurements of the celiac axis (CA), superior mesenteric artery (SMA), left renal artery (LRA), and right renal artery (RRA) included ostial distance and branching angle relative to the CA. A greedy set-cover algorithm identified the smallest number of OTS configurations achieving fenestration target vessel alignment (FTVA). Cumulative coverage and clustering by aortic diameter were assessed. Analyses were exploratory and descriptive. RESULTS: Anatomic data were available in 57.1% of cases for the SMA, 96.1% for the LRA, and 96.8% for the RRA. The CA served as the reference point for all analyses. Eight configurations covered 81.9% of SMA, 49.7% of LRA, and 52.9% of RRA anatomies. SMA coverage exceeded 90% with 16 designs, whereas 20 configurations were required for each renal artery to reach 80% coverage. No clustering of vessel origin by aortic diameter (median, 28 mm; interquartile range, 26-30.5 mm) was observed. Below 70% coverage for three-vessel and
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular and Endovascular Surgery, Klinik Ottakring, Vienna, Austria. Electronic address: ah.reply@outlook.com.
- Department of Vascular and Endovascular Surgery, Klinik Ottakring, Vienna, Austria.
Zitieren
APA
Hofmann, A., Leinweber, M., Kliewer, M., Taher, F., Assadian, A., & Plimon, M. (2026). Anatomic feasibility of off-the-shelf fenestrated endovascular aneurysm repair devices: An anatomic study. Journal of Vascular Surgery. https://doi.org/10.1016/j.jvs.2026.05.038
Vancouver
Hofmann A, Leinweber M, Kliewer M, Taher F, Assadian A, Plimon M. Anatomic feasibility of off-the-shelf fenestrated endovascular aneurysm repair devices: An anatomic study. Journal of Vascular Surgery. 2026. doi:10.1016/j.jvs.2026.05.038
BibTeX
@article{Hofmann2026,
author = {Hofmann, Amun and Leinweber, Maria and Kliewer, Miriam and Taher, Fadi and Assadian, Afshin and Plimon, Markus},
title = {Anatomic feasibility of off-the-shelf fenestrated endovascular aneurysm repair devices: An anatomic study},
journal = {Journal of Vascular Surgery},
year = {2026},
doi = {10.1016/j.jvs.2026.05.038}
}
EUVIMED