EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Computed tomography-based anatomical suitability of an Endo-Bentall prosthesis for ascending aortic aneurysms

Mustafa Aldag, Petroula Nana, Giuseppe Panuccio, José I Torrealba, Niklas Schofer, Konstantinos Spanos, Yskert von Kodolitsch, Jens Brickwedel, Till Joscha Demal, Christian Detter, Tilo Kölbel

Journal of Vascular Surgery · 2025

DOI: 10.1016/j.jvs.2024.10.084 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vascular Surgery, 2025. Verfasst von Mustafa Aldag und 10 weiteren Autor:innen. Beteiligte Einrichtung: German Aortic Center, Department of Vascular Medicine, University Medical Center Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Blood Vessel Prosthesis, Endovascular Procedures, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study aimed to evaluate the suitability of a coronary-branched ascending aortic endograft, paired with aortic valve (AV) prosthesis (Endo-Bentall), for the endovascular repair of ascending aortic aneurysms. METHODS: Preoperative ≤1 mm computed tomography angiographies of consecutive patients managed with Bentall procedure or ascending aortic replacement and AV reconstruction/replacement, in a single institution (from January 1, 2008, to December 31, 2023), were retrospectively analyzed. Dedicate software was used to assess (1) vascular access, (2) proximal landing zone, (3) coronary artery anatomy, and (4) distal landing. Eligibility criteria for Endo-Bentall were ≥8 mm iliac arteries, without severe calcification/tortuosity, proximal landing with an 18- to 29-mm aortic annulus diameter, ≥10 mm annulus-coronary ostium distance, no mechanical AV, absence of coronary grafts in the ascending aorta, no left ventricle thrombus, coronary arteries ≥3 mm wide and ≥10 mm long, with no anatomical abnormalities, ostial stent or stenosis, and ≥20 mm long and ≤38 mm wide distal landing zone within the ascending aorta or applicability of branched endovascular arch repair. RESULTS: Twenty-nine patients (55.2% females) were included. All patients had adequate proximal landing zone in terms of annulus diameter (median, 25 mm; interquartile range [IQR], 5 mm). Two (6.8%) had inadequate iliac access (external iliac artery

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyBlood Vessel ProsthesisEndovascular ProceduresBlood Vessel Prosthesis ImplantationAortographyAortic AneurysmHeart Valve ProsthesisHeart Valve Prosthesis ImplantationAortaHumansRetrospective StudiesFemaleMaleAgedTreatment OutcomeProsthesis DesignMiddle AgedAged, 80 and overPredictive Value of TestsAneurysm, Ascending Aorta

Stichwörter der Autor:innen

AnatomyAscending aorta aneurysmEndo-BentallEndovascular repairSuitability

Autor:innen und Institutionen

  • German Aortic Center, Department of Vascular Medicine, University Medical Center Eppendorf, Hamburg, Germany.
  • German Aortic Center, Department of Vascular Medicine, University Medical Center Eppendorf, Hamburg, Germany. Electronic address: petr.nana7@hotmail.com.
  • German Aortic Center, Department of Cardiology, University Medical Center Eppendorf, Hamburg, Germany.
  • German Aortic Center, Department of Cardiovascular Surgery, University Medical Center Eppendorf, Hamburg, Germany.

Zitieren

APA

Aldag, M., Nana, P., Panuccio, G., Torrealba, J. I., Schofer, N., Spanos, K., von Kodolitsch, Y., Brickwedel, J., Demal, T. J., Detter, C., & Kölbel, T. (2025). Computed tomography-based anatomical suitability of an Endo-Bentall prosthesis for ascending aortic aneurysms. Journal of Vascular Surgery. https://doi.org/10.1016/j.jvs.2024.10.084

Vancouver

Aldag M, Nana P, Panuccio G, Torrealba JI, Schofer N, Spanos K, et al. Computed tomography-based anatomical suitability of an Endo-Bentall prosthesis for ascending aortic aneurysms. Journal of Vascular Surgery. 2025. doi:10.1016/j.jvs.2024.10.084

BibTeX
@article{Aldag2025,
  author = {Aldag, Mustafa and Nana, Petroula and Panuccio, Giuseppe and Torrealba, José I and Schofer, Niklas and Spanos, Konstantinos and von Kodolitsch, Yskert and Brickwedel, Jens and Demal, Till Joscha and Detter, Christian and Kölbel, Tilo},
  title = {Computed tomography-based anatomical suitability of an Endo-Bentall prosthesis for ascending aortic aneurysms},
  journal = {Journal of Vascular Surgery},
  year = {2025},
  doi = {10.1016/j.jvs.2024.10.084}
}
Kostenlos starten →