Multizentrische Studie in der Zeitschrift Journal of Vascular Surgery, 2024. Verfasst von Nicola Leone und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, Ospedale Civile di Baggiovara, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio Emilia, M…. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis Implantation, Aortic Aneurysm, Thoracic, Aortic Aneurysm, Abdominal, Endovascular Procedures. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: We compared the outcomes of patients treated with nonbare stents (NBS) and proximal bare stents (PBS) endografts with a proximal landing zone in the aortic arch during thoracic endovascular aortic repair (TEVAR). METHODS: We conducted a retrospective cohort, observational, multicenter study that included 361 consecutive TEVAR procedures undertaken between November 2005 and December 2021. TEVAR patients with both BS and NBS Relay stent graft configurations with proximal landing in zones 1, 2, or 3 were enrolled. Preoperative anamnestic and morphological data, clinical outcomes, and aortic modifications 30 days after surgery and at the latest follow-up available were collected. The primary outcome was freedom from proximal endoleak (type IA) comparing the two configurations. Total and detailed endoleak rates, clinical and technical success, intraoperative additional maneuvers, major adverse events, and reinterventions were secondary outcomes. RESULTS: The median follow-up was 4.9 (interquartile range, 2.0-8.1) years. No statistically significant difference between NBS and PBS patients concerning 30-day major adverse events, retrograde aortic dissection, disabling stroke, or late type IA endoleak (10.8% vs 7.8%; P = .597). Aneurysmal disease (P = .026), PLZ diameter of >34 mm (P = .026), aortic tortuosity index of >1.4 (P = .008), type III aortic arch (P = .068), and PLZ thrombus (P = .014) identified as risk factors by univariate Cox regression analysis. PLZ thrombus was the only type IA endoleak risk factor at multivariate Cox regression (P = .016). CONCLUSIONS: We found no statistically significant difference in freedom from type IA endoleak, retrograde dissection, or disabling stroke observed between the NBS and the BS configuration of the Relay endograft. Proximal landing zone thrombotic apposition was a prominent risk factor for type IA endoleak after TEVAR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Vessel Prosthesis ImplantationAortic Aneurysm, ThoracicAortic Aneurysm, AbdominalEndovascular ProceduresStrokeThrombosisHumansAorta, ThoracicEndovascular Aneurysm RepairBlood Vessel ProsthesisEndoleakRetrospective StudiesTreatment OutcomeProsthesis DesignTime FactorsStents

Stichwörter der Autor:innen

Aortic archEndoleakNonbare stentProximal bare stentTEVAR

Autor:innen und Institutionen

  • Department of Vascular Surgery, Ospedale Civile di Baggiovara, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio Emilia, Modena, Italy. Electronic address: nicola.leone.md@gmail.com.
  • Department of Vascular Surgery, Ospedale Civile di Baggiovara, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio Emilia, Modena, Italy.
  • Clinic for Cardiovascular Surgery, University Heart Centre, Freiburg, Germany.
  • Department of Vascular Surgery, Ospedale Civile di Baggiovara, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio Emilia, Modena, Italy; Clinic for Cardiovascular Surgery, University Heart Cent…

Zitieren

APA

Leone, N., Bartolotti, L. A. M., Capitain, A. N., Migliari, M., Silingardi, R., Czerny, M., Rylski, B., & Gennai, S. (2024). Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch. Journal of Vascular Surgery. https://doi.org/10.1016/j.jvs.2023.12.034

Vancouver

Leone N, Bartolotti LAM, Capitain AN, Migliari M, Silingardi R, Czerny M, et al. Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch. Journal of Vascular Surgery. 2024. doi:10.1016/j.jvs.2023.12.034

BibTeX
@article{Leone2024,
  author = {Leone, Nicola and Bartolotti, Luigi A M and Capitain, André N and Migliari, Mattia and Silingardi, Roberto and Czerny, Martin and Rylski, Bartosz and Gennai, Stefano},
  title = {Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch},
  journal = {Journal of Vascular Surgery},
  year = {2024},
  doi = {10.1016/j.jvs.2023.12.034}
}
Kostenlos starten →