Spinal drain-related complications after complex endovascular aortic repair using a prophylactic automated volume-directed drainage protocol
Journal of Vascular Surgery · 2023
DOI: 10.1016/j.jvs.2023.03.505 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Journal of Vascular Surgery, 2023. Verfasst von Gísli Gunnar Jónsson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden. Electronic address: gisli.jonsson@surgsci.uu.se. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Spinal Cord Ischemia, Endovascular Procedures. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: A common measure to lower the risk for spinal cord ischemia (SCI) during complex endovascular aortic repair (cEVAR) is prophylactic cerebrospinal fluid drainage (CSFD). This method has caused controversy because of drain-related complications. Spinal drains are usually pressure directed. The objective of this study was to evaluate the risk of CSFD-related complications and SCI within the context of an automated volume-directed drain protocol. METHODS: This is a retrospective, single-center study of all cEVARs with CSFD at a tertiary vascular center between January 2014 and December 2020. Demographics, complications, and spinal drain data were recorded. All drainages were volume based using an automatic drainage system (LiquoGuard7; Möller Medical GmbH). Spinal drain complications were categorized as disabling and nondisabling according to the modified Rankin scale. The primary end point was any CSFD-related complication. RESULTS: A total of 448 cEVAR patients were identified, of whom 147 (32.8%) had prophylactic CSFD. The mean age was 69 years (63% male). The most common pathology (61%) was thoracoabdominal aortic aneurysm, and the most common procedure was branched EVAR (55.1%). Eighteen (12.2%) patients developed a CSFD-related complication, whereof three (2%) were disabling. Nineteen (13%) patients developed SCI: 12 (8.4%) paraparetic, 5 (3.4%) paraplegic, and 2 (1.4%) paresthesias. Of these, 13 (68%) had full reversal of symptoms, whereas 6 patients (4%) had residual symptoms and were deemed disabling. Drain-related complications were more common in patients with SCI (31.6%) compared with those without (9.4%, P = .014). In the latter group, only two patients (1.6%) developed a disabling drain-related complication. CONCLUSIONS: Selective use of prophylactic, automated volume-directed CSFD in patients at high risk for SCI was associated with a high incidence of complications and should be used with caution. Among those developing SCI, reversal was achieved frequently with increased CSFD volume, but at the price of more bleeding complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden. Electronic address: gisli.jonsson@surgsci.uu.se.
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden.
- Department of Surgical Sciences, Section of Radiology, Uppsala University, Uppsala, Sweden.
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden; Division of Vascular and Endovascular Surgery, Cardiovascular Department, University Hospital of Trieste ASUGI, Trieste,…
- Department of Surgical Sciences, Section of Anesthesiology and Intensive Care, Uppsala University, Uppsala, Sweden.
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden; Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden.
Zitieren
APA
Jónsson, G. G., Mani, K., Mosavi, F., D'Oria, M., Semenas, E., Wanhainen, A., & Lindström, D. (2023). Spinal drain-related complications after complex endovascular aortic repair using a prophylactic automated volume-directed drainage protocol. Journal of Vascular Surgery. https://doi.org/10.1016/j.jvs.2023.03.505
Vancouver
Jónsson GG, Mani K, Mosavi F, D'Oria M, Semenas E, Wanhainen A, et al. Spinal drain-related complications after complex endovascular aortic repair using a prophylactic automated volume-directed drainage protocol. Journal of Vascular Surgery. 2023. doi:10.1016/j.jvs.2023.03.505
BibTeX
@article{Jnsson2023,
author = {Jónsson, Gísli Gunnar and Mani, Kevin and Mosavi, Firas and D'Oria, Mario and Semenas, Egidijus and Wanhainen, Anders and Lindström, David},
title = {Spinal drain-related complications after complex endovascular aortic repair using a prophylactic automated volume-directed drainage protocol},
journal = {Journal of Vascular Surgery},
year = {2023},
doi = {10.1016/j.jvs.2023.03.505}
}
EUVIMED