EUVIMEDEUVIMED entdecken
Crossref

Effect of bridging stent graft selection for directional branches on target artery outcomes of fenestrated-branched endovascular aortic repair in the United States Aortic Research Consortium

Emanuel R Tenorio, Andres Schanzer, Carlos H Timaran, Darren B Schneider, Bernardo C Mendes, Matthew J Eagleton, Mark A Farber, F Ezequiel Parodi, Warren J Gasper, Adam W Beck, Matthew P Sweet, Sara L Zettervall und 3 weitere

Journal of Vascular Surgery · 2023-07 · 78 (1) · 10-28.e3

DOI: 10.1016/j.jvs.2023.03.025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vascular Surgery, 2023-07. Verfasst von Emanuel R Tenorio und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic & Vascular Surgery, Advanced Aortic Research Program at the University of Texas Health Science Center at Houston, McGove…. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis Implantation, Aortic Aneurysm, Thoracic, Endovascular Procedures. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Medtronic, GE Healthcare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The purpose of this study was to evaluate the effect of directional branches (DBs) bridging stent choice on target artery (TA) outcomes during fenestrated-branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms. METHODS: Patients enrolled in nine prospective physician-sponsored investigational device exemption studies in the United States between 2005 and 2020 were analyzed. All patients who had at least one TA incorporated by DB using either self-expandable (SESGs), balloon-expandable (BESGs), or hybrid stent graft combinations (HSGs). Endpoints were TA patency and freedom from TA endoleak, instability, and reintervention. RESULTS: There were 800 patients with 2426 renal-mesenteric arteries incorporated by DBs. DB stent selection was SESGs in 1205 TAs (50%), BESGs in 1095 TAs (45%), and HSGs in 126 TAs (5%). SESGs were predominantly used in the first three quartiles of the study period, whereas BESGs comprised 75% of all stents between 2017 and 2020. The median follow-up was 15 months (interquartile range, 6-35 months). At 5 years, BESGs had significantly lower freedom from TA instability (78% ± 4% vs 88% ± 1% vs 96% ± 2%; log-rank P =.010), freedom from TA endoleaks (87% ± 3% vs 97% ± 1% vs 99% ± 1%; log-rank P < .001), and freedom from TA reintervention (83% ± 4% vs 95% ± 1% vs 99% ± 2%; log-rank P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Vessel Prosthesis ImplantationAortic Aneurysm, ThoracicEndovascular ProceduresHumansUnited StatesBlood Vessel ProsthesisEndoleakEndovascular Aneurysm RepairProspective StudiesRisk FactorsTreatment OutcomeProsthesis DesignStentsArteries

Stichwörter der Autor:innen

Balloon-expandable stent graftsBranch constructionBridging stentComplex abdominal aortic aneurysmDirectional branchesFenestrated-branched endovascular repairSelf-expandable stent graftsThoracoabdominal aortic aneurysm

Autor:innen und Institutionen

  • Department of Cardiothoracic & Vascular Surgery, Advanced Aortic Research Program at the University of Texas Health Science Center at Houston, McGovern Medical School, Houston, TX.
  • Division of Vascular and Endovascular Surgery, University of Massachusetts Medical School, Worcester, MA.
  • Division of Vascular and Endovascular Surgery, University of Texas Southwestern, Dallas, TX.
  • Division of Vascular Surgery and Endovascular Therapy, University of Pennsylvania, Philadelphia, PA.
  • Division of Vascular and Endovascular, Mayo Clinic, Rochester, MN.
  • Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, MA.

Förderung

  • Medtronic
  • GE Healthcare

Zitieren

APA

Tenorio, E. R., Schanzer, A., Timaran, C. H., Schneider, D. B., Mendes, B. C., Eagleton, M. J., Farber, M. A., Parodi, F. E., Gasper, W. J., Beck, A. W., Sweet, M. P., Zettervall, S. L., Huang, Y., Oderich, G. S., & U.S. Fenestrated and Branched Aortic Research Consortium (2023). Effect of bridging stent graft selection for directional branches on target artery outcomes of fenestrated-branched endovascular aortic repair in the United States Aortic Research Consortium. Journal of Vascular Surgery, 78(1), 10-28.e3. https://doi.org/10.1016/j.jvs.2023.03.025

Vancouver

Tenorio ER, Schanzer A, Timaran CH, Schneider DB, Mendes BC, Eagleton MJ, et al. Effect of bridging stent graft selection for directional branches on target artery outcomes of fenestrated-branched endovascular aortic repair in the United States Aortic Research Consortium. Journal of Vascular Surgery. 2023;78(1):10-28.e3. doi:10.1016/j.jvs.2023.03.025

BibTeX
@article{Tenorio2023,
  author = {Tenorio, Emanuel R and Schanzer, Andres and Timaran, Carlos H and Schneider, Darren B and Mendes, Bernardo C and Eagleton, Matthew J and Farber, Mark A and Parodi, F Ezequiel and Gasper, Warren J and Beck, Adam W and Sweet, Matthew P and Zettervall, Sara L and Huang, Ying and Oderich, Gustavo S and U.S. Fenestrated and Branched Aortic Research Consortium, U.S. Fenestrated and Branched Aortic Research Consortium},
  title = {Effect of bridging stent graft selection for directional branches on target artery outcomes of fenestrated-branched endovascular aortic repair in the United States Aortic Research Consortium},
  journal = {Journal of Vascular Surgery},
  year = {2023},
  volume = {78},
  number = {1},
  pages = {10--28.e3},
  doi = {10.1016/j.jvs.2023.03.025}
}
Kostenlos starten →