Utility of Carbon Dioxide Venography and Intraprocedural CT for Adrenal Venous Sampling in Patients with an Allergy to Iodinated Contrast Media
Journal of Vascular and Interventional Radiology · 2023
DOI: 10.1016/j.jvir.2023.07.021 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Vascular and Interventional Radiology, 2023. Verfasst von Hiroki Kamada und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan. Electronic address: hkamada@rad.med.tohoku.ac.jp. Hauptthemen laut MEDLINE: Iodine, Hypersensitivity, Hyperaldosteronism. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
PURPOSE: To assess the diagnostic performance of carbon dioxide (CO2) and intraprocedural unenhanced computed tomography (CT) for adrenal venous sampling (AVS) (CO2-intraprocedural unenhanced CT-AVS) in patients with primary aldosteronism (PA) and a history of iodine contrast medium allergy. MATERIALS AND METHODS: CO2-intraprocedural unenhanced CT-AVS was performed in 18 patients with iodine contrast media allergies at the authors' hospital between December 2015 and January 2021. CT and noncontrast magnetic resonance angiography were used to evaluate the preoperative adrenal vein anatomy. CO2 venography was performed to confirm adrenal vein catheterization. Additionally, intraprocedural unenhanced CT was also performed to confirm catheter position in the right adrenal gland. RESULTS: In all cases in which CO2-intraprocedural unenhanced CT-AVS was performed, the right and left adrenal veins were catheterized appropriately, leading to a localized diagnosis. Catheterization of the left adrenal vein was confirmed using CO2 venography in all cases. In 7 of the 18 cases, CO2 venography demonstrated selection of the right adrenal vein. In 15 of 18 cases, intraprocedural unenhanced CT demonstrated selection of the right adrenal vein. CONCLUSIONS: CO2-intraprocedural unenhanced CT-AVS demonstrated the same diagnostic ability for PA localization as conventional AVS with iodine contrast media. The proposed method is clinically feasible for AVS, in which iodine contrast media use is restricted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan. Electronic address: hkamada@rad.med.tohoku.ac.jp.
- Department of Diagnostic Radiology, South Miyagi Medical Center, Ohgawara, Miyagi, Japan.
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
- Division of Clinical Hypertension, Endocrinology, and Metabolism, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Kamada, H., Seiji, K., Oguro, S., Ota, H., Yanagaki, S., Omata, K., Tezuka, Y., Ono, Y., Morimoto, R., Satoh, F., & Takase, K. (2023). Utility of Carbon Dioxide Venography and Intraprocedural CT for Adrenal Venous Sampling in Patients with an Allergy to Iodinated Contrast Media. Journal of Vascular and Interventional Radiology. https://doi.org/10.1016/j.jvir.2023.07.021
Vancouver
Kamada H, Seiji K, Oguro S, Ota H, Yanagaki S, Omata K, et al. Utility of Carbon Dioxide Venography and Intraprocedural CT for Adrenal Venous Sampling in Patients with an Allergy to Iodinated Contrast Media. Journal of Vascular and Interventional Radiology. 2023. doi:10.1016/j.jvir.2023.07.021
BibTeX
@article{Kamada2023,
author = {Kamada, Hiroki and Seiji, Kazumasa and Oguro, Sota and Ota, Hideki and Yanagaki, Satoru and Omata, Kei and Tezuka, Yuta and Ono, Yoshikiyo and Morimoto, Ryo and Satoh, Fumitoshi and Takase, Kei},
title = {Utility of Carbon Dioxide Venography and Intraprocedural CT for Adrenal Venous Sampling in Patients with an Allergy to Iodinated Contrast Media},
journal = {Journal of Vascular and Interventional Radiology},
year = {2023},
doi = {10.1016/j.jvir.2023.07.021}
}
EUVIMED