Effect of non-ionic contrast media on invasive pressure measurements during minimally invasive occlusion of patent ductus arteriosus and balloon valvuloplasty for valvular pulmonic stenosis in dogs
Journal of Veterinary Cardiology · 2026
DOI: 10.1016/j.jvc.2026.02.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Veterinary Cardiology, 2026. Verfasst von A D Saavedra und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, 900 East Campus Drive, Columbia, MO, 65211, US…. Hauptthemen laut MEDLINE: Ductus Arteriosus, Patent, Contrast Media, Pulmonary Valve Stenosis, Balloon Valvuloplasty. Gefördert von: American College of Veterinary Internal Medicine.
Abstract (Originalsprache)
INTRODUCTION/OBJECTIVES: Hemodynamic effects of non-ionic contrast (iohexol) administration on invasive pressure measurements in dogs have not been evaluated. The objective of the present study was to evaluate effects of iohexol on invasive pressure assessment in dogs undergoing patent ductus arteriosus (PDA) occlusion or balloon valvuloplasty for pulmonic stenosis (PS). ANIMALS, MATERIALS AND METHODS: This is a prospective observational study. Client-owned dogs undergoing PDA occlusion (N=14) or balloon valvuloplasty (N=12) were included in the study. Invasive pressures for PDA dogs (main pulmonary artery and aorta) and PS dogs (right ventricle and main pulmonary artery) were obtained. Heart rate and direct arterial peripheral blood pressure were recorded simultaneously. Pressures were acquired prior to contrast injection (t0), 60-90 s after injection (t1), and 5 min after injection (t2). The mean pressure difference between time points was calculated, including peak-to-peak pressure gradient for PS dogs, as well as 95% tolerance intervals. RESULTS: Differences were found for the following: PDA group: diastolic and mean aortic pressure between t0 and t1 (P=0.019, P=0.003), diastolic aortic pressure between t0 and t2 (P=0.020), and diastolic peripheral arterial pressure between t0 and t2 (P=0.044); PS group: main pulmonary artery systolic pressure between t0 and t1 (P=0.044). Tolerance intervals were often clinically meaningful. STUDY LIMITATIONS: Limitations of the present study include a small population size, lack of anesthetic standardization, absence of a control group, and one brand of non-ionic contrast used. CONCLUSIONS: Although mean pressure changes did not reach significance for most measurements, 95% tolerance intervals suggest large changes can occur. Given the potential for wide variation, invasive pressure measurements should be obtained prior to contrast administration if pressure measurements are utilized for intra-operative surgical decisions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, 900 East Campus Drive, Columbia, MO, 65211, USA.
- Department of Biomedical Informatics, Biostatistics, and Medical Epidemiology (BBME), School of Medicine, University of Missouri, 230 Jesse Hall, Columbia MO, 65211, USA.
- Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, 900 East Campus Drive, Columbia, MO, 65211, USA. Electronic address: wiggenk@missouri.edu.
Förderung
- American College of Veterinary Internal Medicine
Zitieren
APA
Saavedra, A. D., Karnia, J., Leach, S. B., Petroski, G. F., Nafe, L., McManamey, A. K., & Wiggen, K. E. (2026). Effect of non-ionic contrast media on invasive pressure measurements during minimally invasive occlusion of patent ductus arteriosus and balloon valvuloplasty for valvular pulmonic stenosis in dogs. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2026.02.003
Vancouver
Saavedra AD, Karnia J, Leach SB, Petroski GF, Nafe L, McManamey AK, et al. Effect of non-ionic contrast media on invasive pressure measurements during minimally invasive occlusion of patent ductus arteriosus and balloon valvuloplasty for valvular pulmonic stenosis in dogs. Journal of Veterinary Cardiology. 2026. doi:10.1016/j.jvc.2026.02.003
BibTeX
@article{Saavedra2026,
author = {Saavedra, A D and Karnia, J and Leach, S B and Petroski, G F and Nafe, L and McManamey, A K and Wiggen, K E},
title = {Effect of non-ionic contrast media on invasive pressure measurements during minimally invasive occlusion of patent ductus arteriosus and balloon valvuloplasty for valvular pulmonic stenosis in dogs},
journal = {Journal of Veterinary Cardiology},
year = {2026},
doi = {10.1016/j.jvc.2026.02.003}
}
EUVIMED