EUVIMEDEUVIMED entdecken
Crossref

Balloon aortic valvuloplasty for congenital aortic valvar stenosis in 10 dogs

R L Winter, B A Scansen, K L Maneval, C S Ferrel, B M Potter, M K Ames, P-T Liao, S W Jung

Journal of Veterinary Cardiology · 2025

DOI: 10.1016/j.jvc.2025.03.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Cardiology, 2025. Verfasst von R L Winter und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, College of Veterinary Medicine, Auburn University, Auburn, AL, 36832, USA. Electronic address: rlw0041@auburn.edu. Hauptthemen laut MEDLINE: Balloon Valvuloplasty, Dog Diseases, Aortic Valve Stenosis. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION/OBJECTIVES: Aortic valvar stenosis (AS) is an uncommon congenital defect in the dog, but when present, it can cause severe clinical signs including collapse and congestive heart failure. In human patients, AS is a common congenital defect that has been managed with balloon aortic valvuloplasty (BAV). The objectives of this study were to describe the procedural details and retrospectively evaluate the outcomes of dogs with severe AS that underwent BAV. ANIMALS: Ten client-owned dogs diagnosed with severe AS. MATERIALS AND METHODS: Medical records and stored images from echocardiographic and angiographic examinations were reviewed from dogs that were diagnosed with severe AS and underwent BAV. The severity of velocity-derived maximal systolic pressure gradient across the aortic valve and aortic insufficiency was assessed from transthoracic echocardiographic images before and after BAV. Procedural details from the BAV procedures including intra-operative complications, type and size of the balloon catheter used, and use of rapid right ventricular pacing were recorded. RESULTS: The median (range) age and weight at the time of BAV were 12 months (6-120 months) and 18.2 kg (4.8-33.0 kg), respectively. Most dogs had high-pressure balloon dilation catheters used (n = 6/10) during BAV, and the balloon diameter-to-aortic annular ratio was 1.03 ± 0.05 for all dogs. The maximal systolic pressure gradient across the aortic valve decreased from 183.2 mmHg ± 74.6 before BAV to 97.4 mmHg ± 48.2 immediately after BAV (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Balloon ValvuloplastyDog DiseasesAortic Valve StenosisAnimalsDogsRetrospective StudiesMaleFemaleEchocardiographyTreatment Outcome

Stichwörter der Autor:innen

CanineInterventionalStenotic

Autor:innen und Institutionen

  • Department of Clinical Sciences, College of Veterinary Medicine, Auburn University, Auburn, AL, 36832, USA. Electronic address: rlw0041@auburn.edu.
  • Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, 300 W Drake Rd., Fort Collins, CO, 80525, USA.
  • Department of Clinical Sciences, College of Veterinary Medicine, Auburn University, Auburn, AL, 36832, USA.

Zitieren

APA

Winter, R. L., Scansen, B. A., Maneval, K. L., Ferrel, C. S., Potter, B. M., Ames, M. K., Liao, P. T., & Jung, S. W. (2025). Balloon aortic valvuloplasty for congenital aortic valvar stenosis in 10 dogs. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2025.03.004

Vancouver

Winter RL, Scansen BA, Maneval KL, Ferrel CS, Potter BM, Ames MK, et al. Balloon aortic valvuloplasty for congenital aortic valvar stenosis in 10 dogs. Journal of Veterinary Cardiology. 2025. doi:10.1016/j.jvc.2025.03.004

BibTeX
@article{Winter2025,
  author = {Winter, R L and Scansen, B A and Maneval, K L and Ferrel, C S and Potter, B M and Ames, M K and Liao, P-T and Jung, S W},
  title = {Balloon aortic valvuloplasty for congenital aortic valvar stenosis in 10 dogs},
  journal = {Journal of Veterinary Cardiology},
  year = {2025},
  doi = {10.1016/j.jvc.2025.03.004}
}
Kostenlos starten →