EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Platelet function analyzer (PFA-100) in patients with mild-to-moderate bleeding disorders and bleeding disorder of unknown cause

Dino Mehic, Bernhard Eichinger, Tim Dreier, Alexander Tolios, Beate Eichelberger, Alexandra Kaider, Cihan Ay, Ingrid Pabinger, Johanna Gebhart

Journal of Thrombosis and Haemostasis · 2025

DOI: 10.1016/j.jtha.2025.01.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Thrombosis and Haemostasis, 2025. Verfasst von Dino Mehic und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria. Electronic address: https://twitt…. Hauptthemen laut MEDLINE: Platelet Function Tests, Hemorrhage, Blood Platelets, Hemorrhagic Disorders. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Central Bank, CSL Behring.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The sensitivity of the platelet function analyzer (PFA-100, Dade Behring Inc) was shown to be high for the detection of von Willebrand disease (VWD), but limited for platelet function defects. OBJECTIVES: To study the diagnostic utility of PFA-100 in mild-to-moderate bleeding disorders and bleeding disorder of unknown cause (BDUC). METHODS: PFA-100 closure times (CTs) were measured with collagen-epinephrine (EPI) and collagen-adenosine diphosphate (ADP) cartridges in 818 patients with mild bleeding disorders from the Vienna Bleeding Biobank. Patients on anticoagulation or antiplatelet therapy or thrombocytopenic patients were not included. RESULTS: Only 2% of the 532 BDUC patients had prolonged CTs in PFA (EPI) and PFA (ADP), and 64% in either PFA (EPI) or PFA (ADP). In total, 34% of BDUC patients did not have prolonged CTs in PFA (EPI) or PFA (ADP). These rates were similar to patients with coagulation factor deficiencies (n = 27). The rate of pathologic CTs was significantly higher in patients with VWD (n = 79) and, although less pronounced, in platelet function defect (n = 180). In 15 of 18 (83%) VWD patients with von Willebrand factor (VWF) antigen and/or VWF ristocetin cofactor activity levels

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Platelet Function TestsHemorrhageBlood PlateletsHemorrhagic DisordersHumansMaleFemaleMiddle AgedAdultAgedvon Willebrand DiseasesCollagenSeverity of Illness IndexPredictive Value of Tests

Stichwörter der Autor:innen

blood coagulation disordersblood losshemorrhageinheritedsurgicalthrombastheniavon Willebrand diseases

Substanzen

Collagen

Autor:innen und Institutionen

  • Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria. Electronic address: https://twitter.com/dino_mehic.
  • Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria.
  • Department of Transfusion Medicine and Cell Therapy, Medical University of Vienna, Vienna, Austria.
  • Institute of Clinical Biometrics, Center for Medical Data Science, Medical University of Vienna, Vienna, Austria.
  • Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria. Electronic address: https://twitter.com/Cihan_Ay_MD.
  • Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria. Electronic address: https://twitter.com/IngridPabinger.

Förderung

  • Austrian Central Bank
  • CSL Behring

Zitieren

APA

Mehic, D., Eichinger, B., Dreier, T., Tolios, A., Eichelberger, B., Kaider, A., Ay, C., Pabinger, I., & Gebhart, J. (2025). Platelet function analyzer (PFA-100) in patients with mild-to-moderate bleeding disorders and bleeding disorder of unknown cause. Journal of Thrombosis and Haemostasis. https://doi.org/10.1016/j.jtha.2025.01.011

Vancouver

Mehic D, Eichinger B, Dreier T, Tolios A, Eichelberger B, Kaider A, et al. Platelet function analyzer (PFA-100) in patients with mild-to-moderate bleeding disorders and bleeding disorder of unknown cause. Journal of Thrombosis and Haemostasis. 2025. doi:10.1016/j.jtha.2025.01.011

BibTeX
@article{Mehic2025,
  author = {Mehic, Dino and Eichinger, Bernhard and Dreier, Tim and Tolios, Alexander and Eichelberger, Beate and Kaider, Alexandra and Ay, Cihan and Pabinger, Ingrid and Gebhart, Johanna},
  title = {Platelet function analyzer (PFA-100) in patients with mild-to-moderate bleeding disorders and bleeding disorder of unknown cause},
  journal = {Journal of Thrombosis and Haemostasis},
  year = {2025},
  doi = {10.1016/j.jtha.2025.01.011}
}
Kostenlos starten →