A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies
Journal of Thrombosis and Haemostasis · 2025
DOI: 10.1016/j.jtha.2024.11.020 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Thrombosis and Haemostasis, 2025. Verfasst von Masayuki Kubo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hematology, Nara Medical University, Kashihara, Japan; Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Ja…. Hauptthemen laut MEDLINE: Luminescent Measurements, Autoantibodies, Purpura, Thrombotic Thrombocytopenic, ADAM Proteins. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Thrombotic thrombocytopenic purpura (TTP) is a fatal disease caused by severe deficiency in ADAMTS-13 (a disintegrin and metalloproteinase with thrombospondin type 1 motifs 13) activity. ADAMTS-13 activity measurement is essential for the diagnosis of TTP, but conventional standard assays are manual and time-consuming. Automated ADAMTS-13 activity assays have recently become available; however, their accuracy remains challenging. OBJECTIVES: We here developed a novel chemiluminescent enzyme immunoassay (CLEIA) for ADAMTS-13 activity that is fully automated, highly sensitive, and has a short reaction time (17 minutes). We evaluated the utility of our fully automated CLEIA for measuring ADAMTS-13 activity and inhibitory antibodies and compared it with conventional manual assays. METHODS: We compared our CLEIA for ADAMTS-13 activity and inhibitory antibodies with an in-house FRETS-VWF73 assay and commercial enzyme-linked immunosorbent assay (ELISA) using samples from 100 patients and 50 healthy donors. Agreement between assays was evaluated using a cutoff value of 10 international units/dL for ADAMTS-13 activity and 0.5 Bethesda units/mL for inhibitory antibodies. RESULTS: The CLEIA and conventional assays for ADAMTS-13 activity correlated well. The CLEIA showed high agreement with the FRETS-VWF73 assay (kappa = 0.96) and ELISA (kappa = 1.0) in classifying patients with a cutoff value of 10 international units/dL for ADAMTS-13 activity. Furthermore, in classifying patients with the cutoff value of 0.5 Bethesda units/mL for inhibitory antibodies, the CLEIA agreed strongly with the FRETS-VWF73 assay (kappa = 0.95) and ELISA (kappa = 0.98). Its diagnostic performance for TTP was satisfactory. CONCLUSION: The high-performance and fully automated CLEIA enables rapid in-hospital diagnosis and follow-up of TTP, as well as detection of inhibitory ADAMTS-13 autoantibodies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Hematology, Nara Medical University, Kashihara, Japan; Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Japan.
- Protein Technology Group, Reagent Engineering, Sysmex Corporation, Kobe, Japan.
- Hemostasis Business Development, ICH Business, Sysmex Corporation, Kobe, Japan.
- Research Laboratory, KAINOS Laboratories, Inc, Tokyo, Japan.
- Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Japan; Japanese Red Cross Kinki Block Blood Center, Osaka, Japan.
- Department of Hematology, Nara Medical University, Kashihara, Japan; Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Japan. Electronic address: mmatsumo@naramed-u.ac.jp.
Zitieren
APA
Kubo, M., Konko, K., Kinoshita, E., Uemae, S., Kobayashi, K., Hayashi, Y., Kan, A., Fujimura, Y., & Matsumoto, M. (2025). A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies. Journal of Thrombosis and Haemostasis. https://doi.org/10.1016/j.jtha.2024.11.020
Vancouver
Kubo M, Konko K, Kinoshita E, Uemae S, Kobayashi K, Hayashi Y, et al. A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies. Journal of Thrombosis and Haemostasis. 2025. doi:10.1016/j.jtha.2024.11.020
BibTeX
@article{Kubo2025,
author = {Kubo, Masayuki and Konko, Kazuyasu and Kinoshita, Emi and Uemae, Satoshi and Kobayashi, Katsushi and Hayashi, Yoshinori and Kan, Akihiko and Fujimura, Yoshihiro and Matsumoto, Masanori},
title = {A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies},
journal = {Journal of Thrombosis and Haemostasis},
year = {2025},
doi = {10.1016/j.jtha.2024.11.020}
}
EUVIMED