EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies

Masayuki Kubo, Kazuyasu Konko, Emi Kinoshita, Satoshi Uemae, Katsushi Kobayashi, Yoshinori Hayashi, Akihiko Kan, Yoshihiro Fujimura, Masanori Matsumoto

Journal of Thrombosis and Haemostasis · 2025

DOI: 10.1016/j.jtha.2024.11.020 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Thrombosis and Haemostasis, 2025. Verfasst von Masayuki Kubo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hematology, Nara Medical University, Kashihara, Japan; Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Ja…. Hauptthemen laut MEDLINE: Luminescent Measurements, Autoantibodies, Purpura, Thrombotic Thrombocytopenic, ADAM Proteins. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Thrombotic thrombocytopenic purpura (TTP) is a fatal disease caused by severe deficiency in ADAMTS-13 (a disintegrin and metalloproteinase with thrombospondin type 1 motifs 13) activity. ADAMTS-13 activity measurement is essential for the diagnosis of TTP, but conventional standard assays are manual and time-consuming. Automated ADAMTS-13 activity assays have recently become available; however, their accuracy remains challenging. OBJECTIVES: We here developed a novel chemiluminescent enzyme immunoassay (CLEIA) for ADAMTS-13 activity that is fully automated, highly sensitive, and has a short reaction time (17 minutes). We evaluated the utility of our fully automated CLEIA for measuring ADAMTS-13 activity and inhibitory antibodies and compared it with conventional manual assays. METHODS: We compared our CLEIA for ADAMTS-13 activity and inhibitory antibodies with an in-house FRETS-VWF73 assay and commercial enzyme-linked immunosorbent assay (ELISA) using samples from 100 patients and 50 healthy donors. Agreement between assays was evaluated using a cutoff value of 10 international units/dL for ADAMTS-13 activity and 0.5 Bethesda units/mL for inhibitory antibodies. RESULTS: The CLEIA and conventional assays for ADAMTS-13 activity correlated well. The CLEIA showed high agreement with the FRETS-VWF73 assay (kappa = 0.96) and ELISA (kappa = 1.0) in classifying patients with a cutoff value of 10 international units/dL for ADAMTS-13 activity. Furthermore, in classifying patients with the cutoff value of 0.5 Bethesda units/mL for inhibitory antibodies, the CLEIA agreed strongly with the FRETS-VWF73 assay (kappa = 0.95) and ELISA (kappa = 0.98). Its diagnostic performance for TTP was satisfactory. CONCLUSION: The high-performance and fully automated CLEIA enables rapid in-hospital diagnosis and follow-up of TTP, as well as detection of inhibitory ADAMTS-13 autoantibodies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Luminescent MeasurementsAutoantibodiesPurpura, Thrombotic ThrombocytopenicADAM ProteinsHumansADAMTS13 ProteinEnzyme-Linked Immunosorbent AssayReproducibility of ResultsAutomationCase-Control StudiesMaleFemaleMiddle AgedAutomation, LaboratoryAdultPredictive Value of TestsAged

Stichwörter der Autor:innen

ADAMTS-13 proteinautoantibodieschemiluminescent assaysinhibitorsthrombotic thrombocytopenic purpura

Substanzen

ADAMTS13 ProteinADAMTS13 protein, humanAutoantibodiesADAM Proteins

Autor:innen und Institutionen

  • Department of Hematology, Nara Medical University, Kashihara, Japan; Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Japan.
  • Protein Technology Group, Reagent Engineering, Sysmex Corporation, Kobe, Japan.
  • Hemostasis Business Development, ICH Business, Sysmex Corporation, Kobe, Japan.
  • Research Laboratory, KAINOS Laboratories, Inc, Tokyo, Japan.
  • Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Japan; Japanese Red Cross Kinki Block Blood Center, Osaka, Japan.
  • Department of Hematology, Nara Medical University, Kashihara, Japan; Department of Blood Transfusion Medicine, Nara Medical University, Kashihara, Japan. Electronic address: mmatsumo@naramed-u.ac.jp.

Zitieren

APA

Kubo, M., Konko, K., Kinoshita, E., Uemae, S., Kobayashi, K., Hayashi, Y., Kan, A., Fujimura, Y., & Matsumoto, M. (2025). A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies. Journal of Thrombosis and Haemostasis. https://doi.org/10.1016/j.jtha.2024.11.020

Vancouver

Kubo M, Konko K, Kinoshita E, Uemae S, Kobayashi K, Hayashi Y, et al. A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies. Journal of Thrombosis and Haemostasis. 2025. doi:10.1016/j.jtha.2024.11.020

BibTeX
@article{Kubo2025,
  author = {Kubo, Masayuki and Konko, Kazuyasu and Kinoshita, Emi and Uemae, Satoshi and Kobayashi, Katsushi and Hayashi, Yoshinori and Kan, Akihiko and Fujimura, Yoshihiro and Matsumoto, Masanori},
  title = {A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies},
  journal = {Journal of Thrombosis and Haemostasis},
  year = {2025},
  doi = {10.1016/j.jtha.2024.11.020}
}
Kostenlos starten →