EUVIMEDEUVIMED entdecken
Fallbericht

Mitral valve transplantation: A valuable option?

Muhammed Ikbal Aydin, Sofia Hanabergh, Ryan O'Hara, Yue-Hin Loke, Sarah Clauss, Niti Dham, Sam Paul Gulino, Joseph W Turek, Yves d'Udekem

The Journal of Thoracic and Cardiovascular Surgery · 2026-10

DOI: 10.1016/j.jtcvs.2026.09.019 ↗

Kurz gefasst

Fallbericht in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2026-10. Verfasst von Muhammed Ikbal Aydin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Surgery, Children's National Hospital, Washington, DC. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE Partial heart transplantation (PHT) offers a growth-accommodating alternative to mechanical valve replacement in congenital heart disease. While experience with semilunar valve PHT is expanding, application to atrioventricular valves remains extremely limited. We report the first mitral valve PHT at our institution, focusing on technical considerations and lessons learned. CASE SUMMARY A 12-year-old patient with prior ventricular septal defect closure and supra-annular implantation of a 21-mm mechanical mitral valve due to congenital stenosis developed prosthetic stenosis (mean gradient 18 mm Hg). Evaluation confirmed suitability for mitral valve PHT using an allogenic donor valve. Preoperative CT imaging guided assessment of chordal length, as native papillary muscles were absent. Following removal of the prosthesis, expanded polytetrafluoroethylene sutures were placed on the left ventricular free wall, matched to donor chordal length and anchored near the papillary bases in anticipation of necrosis. The donor valve, retained with a small muscular rim, was secured to the native annulus and tested for competence. An additional suture was placed on the central papillary subhead. Recovery was uneventful, and the patient was discharged on immunosuppression. At four months, MRI demonstrated severe mitral regurgitation (regurgitant fraction 53%) due to anterior leaflet prolapse. The family elected mechanical replacement. Intraoperatively, the transplanted valve showed complete annular integration and tissue viability. Histopathology confirmed papillary necrosis with fibroblast infiltration, while leaflets and chordae remained viable. CONCLUSIONS Mitral valve PHT is feasible and demonstrates valve viability. Durable outcomes may depend on symmetric and balanced reimplantation of the subvalvar apparatus, particularly in patients lacking native papillary muscles.

Autor:innen und Institutionen

  • Division of Cardiac Surgery, Children's National Hospital, Washington, DC.
  • Division of Cardiology, Children's National Hospital, Washington, DC.
  • Department of Pathology and Laboratory Medicine, Children's National Hospital, Washington, DC.
  • Division of Cardiovascular and Thoracic Surgery, Duke Children's Pediatric and Congenital Heart Center, Duke University Medical Center, Durham, NC.
  • Division of Cardiac Surgery, Children's National Hospital, Washington, DC. Electronic address: Yves.DUdekem@childrensnational.org.

Zitieren

APA

Aydin, M. I., Hanabergh, S., O'Hara, R., Loke, Y. H., Clauss, S., Dham, N., Gulino, S. P., Turek, J. W., & d'Udekem, Y. (2026). Mitral valve transplantation: A valuable option?. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2026.09.019

Vancouver

Aydin MI, Hanabergh S, O'Hara R, Loke YH, Clauss S, Dham N, et al. Mitral valve transplantation: A valuable option?. The Journal of Thoracic and Cardiovascular Surgery. 2026. doi:10.1016/j.jtcvs.2026.09.019

BibTeX
@article{Aydin2026,
  author = {Aydin, Muhammed Ikbal and Hanabergh, Sofia and O'Hara, Ryan and Loke, Yue-Hin and Clauss, Sarah and Dham, Niti and Gulino, Sam Paul and Turek, Joseph W and d'Udekem, Yves},
  title = {Mitral valve transplantation: A valuable option?},
  journal = {The Journal of Thoracic and Cardiovascular Surgery},
  year = {2026},
  doi = {10.1016/j.jtcvs.2026.09.019}
}
Kostenlos starten →