EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Ex vivo biomechanical analysis of pulmonary autograft inclusion techniques in the Ross procedure

Alexander K Reed, Chris Huynh, Avi Gupta, David Ahn, Junkai Yang, Matthew Leipzig, Yuanjia Zhu, Gabe Weininger, Stefan Elde, Y Joseph Woo

The Journal of Thoracic and Cardiovascular Surgery · 2026-07

DOI: 10.1016/j.jtcvs.2026.07.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2026-07. Verfasst von Alexander K Reed und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif; Cardiovascular Institute, Stanford University, Palo Alto, Calif. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The Ross procedure synthetic inclusion technique seeks to limit autograft dilation by enclosing it within a synthetic graft, yet its influence on neoaortic valve function is incompletely characterized. We sought to assess whether different inclusion techniques alter neoaortic leaflet or sinus function. METHODS: Eight porcine pulmonic roots were harvested with aortic controls for assessment in a 3-dimensional printed left-heart simulator in the following conditions: unsupported autograft, external annular ring and sinotubular (STJ) straight graft, Valsalva graft inclusion technique, and straight graft inclusion technique. Hemodynamic, kinematic, and echocardiographic outcomes were measured in systemic and pulmonic conditions. RESULTS: Valves within a straight graft had higher transvalvular gradients (7.01 ± 0.96 mm Hg) compared with the annular/sinotubular junction (1.33 ± 0.96 mm Hg), unsupported (3.42 ± 0.96 mm Hg) and control groups (aortic control [AC], 3.72 ± 0.96; pulmonic control [PC], 1.47 ± 0.96 mm Hg, P < .01). All conditions had similar leaflet velocities, but the Valsalva condition had higher relative opening forces (1.81 ± 0.21) compared with the annular/STJ (0.93 ± 0.21), unsupported (0.98 ± 0.21) and control (AC, 1.00 ± 0.21; PC, 0.97 ± 0.21) conditions (P < .01). Leaflet forces normalized with Valsalva sinus modification (2-mm slit). Root strain was higher in pulmonic controls (18.21 ± 2.35%; P < .01) while maximum sinus diameter was reduced in the straight graft and pulmonic control conditions relative to supported and unsupported techniques (P < .01). In a sensitivity analysis of only systemic conditions, more restrictive inclusion techniques had significantly reduced root strain relative to the annular/ STJ support condition (P < .01). CONCLUSIONS: We demonstrate that autografts implanted within common inclusion techniques achieve leaflet and sinus performance comparable to native, unsupported autografts, while likely mitigating the risks of future autograft dilatation and neoaortic insufficiency.

Schlagwörter

Stichwörter der Autor:innen

Ross procedureaortic valve replacementinclusion techniquepulmonary autograftpulmonary valve

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif; Cardiovascular Institute, Stanford University, Palo Alto, Calif.
  • Department of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif.
  • Department of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif; Cardiovascular Institute, Stanford University, Palo Alto, Calif; Department of Bioengineering, Stanford University, Palo Alto, Calif. Electron…

Förderung

  • National Institutes of Health

Zitieren

APA

Reed, A. K., Huynh, C., Gupta, A., Ahn, D., Yang, J., Leipzig, M., Zhu, Y., Weininger, G., Elde, S., & Woo, Y. J. (2026). Ex vivo biomechanical analysis of pulmonary autograft inclusion techniques in the Ross procedure. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2026.07.014

Vancouver

Reed AK, Huynh C, Gupta A, Ahn D, Yang J, Leipzig M, et al. Ex vivo biomechanical analysis of pulmonary autograft inclusion techniques in the Ross procedure. The Journal of Thoracic and Cardiovascular Surgery. 2026. doi:10.1016/j.jtcvs.2026.07.014

BibTeX
@article{Reed2026,
  author = {Reed, Alexander K and Huynh, Chris and Gupta, Avi and Ahn, David and Yang, Junkai and Leipzig, Matthew and Zhu, Yuanjia and Weininger, Gabe and Elde, Stefan and Woo, Y Joseph},
  title = {Ex vivo biomechanical analysis of pulmonary autograft inclusion techniques in the Ross procedure},
  journal = {The Journal of Thoracic and Cardiovascular Surgery},
  year = {2026},
  doi = {10.1016/j.jtcvs.2026.07.014}
}
Kostenlos starten →