EUVIMEDEUVIMED entdecken
Open Access

Optimal coronary flow rates for preservation of function during normothermic ex situ heart perfusion

Wyeth D Alexander, Takahiro Nakashima, Vikramjit Chakrabortty, Kristopher A Urrea, Sarah D King, S Sikandar Raza, Martin G Daman, Carol Ling, Ingrid L Bergin, Joseph B Niman, Alvaro Rojas-Peña, Daniel H Drake

The Journal of Thoracic and Cardiovascular Surgery · 2026-05

DOI: 10.1016/j.jtcvs.2026.05.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2026-05. Verfasst von Wyeth D Alexander und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University of Michigan, Ann Arbor, Mich; Department of Surgery, University of California, San Diego, San Diego, Calif. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIH, Frankel Family Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Current clinical normothermic ex situ heart perfusion (NEHP) flow rates, approximately 1.5 cc/g cardiac tissue per minute, are based on lactate level trends. Lactate level alone may not be sufficient for optimizing flow. We sought to identify optimal coronary flow using multiple assays of myocardial preservation. METHODS: Consecutive porcine donor hearts were maintained in our 24-hour NEHP model. Hearts were randomized to 1 of 3 perfusion rates: high flow (HF) 1.5 cc/g/minute, medium flow (MF) 0.75 cc/g/minute, and low flow (LF) 0.25 cc/g/minute (n = 5 each). Data collection included biomarkers, immunohistochemistry, and echocardiography. RESULTS: MF had the least secondary aortic regurgitation (LF 14.0% ± 16.3% vs MF 7.9% ± 3.4% [P < .001] and MF vs HF 14.0% ± 16.3% [P = .023]). HF interventricular septal dimension in diastole increased due to edema (LF 91% ± 8% vs HF 129% ± 11% [P = .024] and MF 84% ± 9% vs HF [P = .013]). HF fatty acid binding proteins and soluble suppression of tumorigenicity-2 levels increased, indicating myocardial injury (LF 0.426 ± 0.13 ng/mL vs HF 1.41 ± 0.70 ng/mL [P = .016], MF 0.021 ± 0.03 ng/mL vs HF [P < .001], and MF 1.06 ± 0.10 ng/mL vs HF 9.53 ± 7.8 ng/mL [P = .013]). Initial LF von Willebrand factor increases indicated endothelial ischemia (LF 11.2 ± 0.9 ng/mL, MF 6.2 ± 1.3 ng/mL, and HF 6.9 ± 0.6 ng/mL; LF vs MF P = .013, LF vs HF P = .026). Histopathology demonstrated autolysis and myofiber degeneration in LF, focal hemorrhage in MF, and extensive hemorrhage, myofiber degeneration, and endothelial damage in HF. Troponin-I immunohistochemistry staining was preserved in MF and markedly diminished in LF and HF. CONCLUSIONS: NEHP coronary flow rates of 0.75 cc/g/minute optimized donor heart function while minimizing injury. This coronary flow rate is substantially less than current clinical practice. Reducing coronary flow during NEHP may improve donor heart preservation and function following transplantation.

Schlagwörter

Stichwörter der Autor:innen

coronary flowechocardiographyex situ heart perfusionheart transplantationlactatemyocardial injuryperfusion

Autor:innen und Institutionen

  • Department of Surgery, University of Michigan, Ann Arbor, Mich; Department of Surgery, University of California, San Diego, San Diego, Calif.
  • Department of Surgery, University of Michigan, Ann Arbor, Mich.
  • Department of Surgery, University of Michigan, Ann Arbor, Mich; Department of Cardiac Surgery, University of Michigan, Ann Arbor, Mich.
  • Department of Cardiac Surgery, University of Michigan, Ann Arbor, Mich.
  • Unit for Laboratory Animal Medicine, University of Michigan, Ann Arbor, Mich.
  • Department of Cardiac Surgery, University of Michigan, Ann Arbor, Mich. Electronic address: daniel.h.drake@gmail.com.

Förderung

  • NHLBI NIH HHS
  • NIH
  • Frankel Family Foundation
  • University of Michigan

Zitieren

APA

Alexander, W. D., Nakashima, T., Chakrabortty, V., Urrea, K. A., King, S. D., Raza, S. S., Daman, M. G., Ling, C., Bergin, I. L., Niman, J. B., Rojas-Peña, A., & Drake, D. H. (2026). Optimal coronary flow rates for preservation of function during normothermic ex situ heart perfusion. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2026.05.006

Vancouver

Alexander WD, Nakashima T, Chakrabortty V, Urrea KA, King SD, Raza SS, et al. Optimal coronary flow rates for preservation of function during normothermic ex situ heart perfusion. The Journal of Thoracic and Cardiovascular Surgery. 2026. doi:10.1016/j.jtcvs.2026.05.006

BibTeX
@article{Alexander2026,
  author = {Alexander, Wyeth D and Nakashima, Takahiro and Chakrabortty, Vikramjit and Urrea, Kristopher A and King, Sarah D and Raza, S Sikandar and Daman, Martin G and Ling, Carol and Bergin, Ingrid L and Niman, Joseph B and Rojas-Peña, Alvaro and Drake, Daniel H},
  title = {Optimal coronary flow rates for preservation of function during normothermic ex situ heart perfusion},
  journal = {The Journal of Thoracic and Cardiovascular Surgery},
  year = {2026},
  doi = {10.1016/j.jtcvs.2026.05.006}
}
Kostenlos starten →