Modeling creatine-kinase MB concentrations following coronary artery bypass grafting
The Journal of Thoracic and Cardiovascular Surgery · 2025
DOI: 10.1016/j.jtcvs.2024.08.019 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2025. Verfasst von Jamie L Romeo und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, University Medical Center, Maastricht University, Maastricht, The Netherlands. Electronic address: jamieromeo@l…. Hauptthemen laut MEDLINE: Coronary Artery Bypass, Creatine Kinase, MB Form, Myocardial Infarction. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: An increase in cardiac biomarkers is a prerequisite for diagnosing periprocedural myocardial infarction (PMI) after coronary artery bypass grafting (CABG). Early-phase risk detection may be aided by modeling time-dependent serum creatine kinase-MB (CK-MB) concentrations. This study aimed to model the kinetics of CK-MB while identifying its influencing factors. METHODS: Patients who underwent elective CABG and had CK-MB measurements within 72 hours postoperatively were included. The primary outcome was the modeled post hoc kinetics of CK-MB in patients without potential PMI. These patients were defined as having no potential PMI based on the absence of ischemic electrocardiographic abnormalities, imaging abnormalities, in-hospital cardiac arrest, mortality, or postoperative unplanned catheterization. A web-based application was created using mixed-effect modeling to provide an interactive and individualized result. RESULTS: A total of 1589 CK-MB measurements from 635 patients who underwent elective isolated CABG were available for analysis. Of these, 609 patients (96%) had no potential PMI and 26 (4%) had potential PMI. Male sex, aortic cross-clamp time, and cardioplegia type significantly impacted CK-MB concentrations. The diagnostic accuracy of the model had an area under the receiver operating characteristic curve of 82.8% (95% confidence interval, 72.6%-90.2%). A threshold of 7 μg/L yielded a sensitivity of 94% and a specificity of 80% (positive predictive value, 17%; negative predictive value, 99%) for excluding potential PMI in our study population. CONCLUSIONS: CK-MB release after CABG depends on the timing of measurement, patient sex, aortic cross-clamp time, and cardioplegia type. The model (available at https://www.cardiomarker.com/ckmb) can be validated, reproduced, refined, and applied to other biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiothoracic Surgery, University Medical Center, Maastricht University, Maastricht, The Netherlands. Electronic address: jamieromeo@live.nl.
- Cardiovascular Research Institute (CARIM), University Medical Center, Maastricht University, Maastricht, The Netherlands; Department of Cardiology, University Medical Center, Maastricht University, Maastricht, The Nethe…
- Department of Cardiothoracic Surgery, University Medical Center, Maastricht University, Maastricht, The Netherlands.
- Department of Cardiothoracic Surgery, Erasmus Medical Center, Rotterdam, The Netherlands.
- Department of Cardiothoracic Surgery, University Medical Center, Maastricht University, Maastricht, The Netherlands; Cardiovascular Research Institute (CARIM), University Medical Center, Maastricht University, Maastrich…
- Department of Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria.
Zitieren
APA
Romeo, J. L., Vriesendorp, P. A., Gerritsen, K., Nader, M., Mahtab, E., Maessen, J. G., Van't Hof, A. W. J., Gollmann-Tepeköylü, C., van Rosmalen, F., van der Horst, I. C. C., Mingels, A. M. A., & Heuts, S. (2025). Modeling creatine-kinase MB concentrations following coronary artery bypass grafting. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2024.08.019
Vancouver
Romeo JL, Vriesendorp PA, Gerritsen K, Nader M, Mahtab E, Maessen JG, et al. Modeling creatine-kinase MB concentrations following coronary artery bypass grafting. The Journal of Thoracic and Cardiovascular Surgery. 2025. doi:10.1016/j.jtcvs.2024.08.019
BibTeX
@article{Romeo2025,
author = {Romeo, Jamie L and Vriesendorp, Pieter A and Gerritsen, Kim and Nader, Musafir and Mahtab, Edris and Maessen, Jos G and Van't Hof, Arnoud W J and Gollmann-Tepeköylü, Can and van Rosmalen, Frank and van der Horst, Iwan C C and Mingels, Alma M A and Heuts, Samuel},
title = {Modeling creatine-kinase MB concentrations following coronary artery bypass grafting},
journal = {The Journal of Thoracic and Cardiovascular Surgery},
year = {2025},
doi = {10.1016/j.jtcvs.2024.08.019}
}
EUVIMED