EUVIMEDEUVIMED entdecken
Crossref

Utility of structured follow-up imaging after aortic surgery

Megan M Chung, Annie Yu, Yanling Zhao, Elizabeth Wist, Yu Hohri, Paul Kurlansky, Jay Leb, Thomas F X O'Donnell, Virendra Patel, Hiroo Takayama

The Journal of Thoracic and Cardiovascular Surgery · 2025-02 · 169 (2) · 584-594.e5

DOI: 10.1016/j.jtcvs.2024.02.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2025-02. Verfasst von Megan M Chung und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiothoracic and Vascular Surgery, NewYork-Presbyterian Hospital, Columbia University Irving Medical Center, New York, NY. Hauptthemen laut MEDLINE: Postoperative Complications, Aorta, Thoracic, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: May and Samuel Rudin Family Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Although postoperative follow-up after aortic surgery is recommended by guidelines, its clinical utility is not well documented. We hypothesized that structured follow-up imaging by an aortic program would improve outcomes. We then documented radiologic findings on asymptomatic postoperative imaging. METHODS: All patients who survived to discharge after open thoracic aortic surgery between January 2017 and July 2021 were included, excluding endocarditis. Patients who followed at our center and received scheduled imaging were compared with patients who did not. Survival was analyzed by the method of Kaplan-Meier, and reintervention was assessed using the Fine-Gray subhazard function. Routine imaging was reviewed for aortic growth, pseudoaneurysm, and perigraft density. RESULTS: After aortic surgery, the cumulative incidence of follow-up was 38.6% at 3 years postoperatively. Patients with follow-up were more likely to have a dissection and fewer comorbidities but were similar in regards to socioeconomic factors and distance to hospital. After matching and accounting for immortal time bias, patients with follow-up had a greater reintervention rate (26.0% vs 9.0%) with similar survival (98.7% vs 95.2%, P = .110) at 4 years. The cumulative incidence of pseudoaneurysm, significant perigraft density, and growth ≥3 mm/year on routine imaging was 49.7% at 3 years. CONCLUSIONS: Implementation of structured follow-up imaging by an aortic program resulted in low clinical compliance. Follow-up was associated with increased rates of aortic reintervention. Clinically relevant radiologic findings were common on asymptomatic imaging and increased throughout 5-year follow-up rather than plateauing in the early postoperative period.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Postoperative ComplicationsAorta, ThoracicBlood Vessel Prosthesis ImplantationHumansMaleFemaleAgedMiddle AgedRetrospective StudiesTime FactorsTreatment OutcomeAneurysm, FalseRisk FactorsPredictive Value of Tests

Stichwörter der Autor:innen

aortic surgeryfollow-up imagingsurveillance imaging

Autor:innen und Institutionen

  • Division of Cardiothoracic and Vascular Surgery, NewYork-Presbyterian Hospital, Columbia University Irving Medical Center, New York, NY.
  • Center for Innovation and Outcomes Research, Columbia University Irving Medical Center, New York, NY.
  • Division of Cardiothoracic and Vascular Surgery, NewYork-Presbyterian Hospital, Columbia University Irving Medical Center, New York, NY; Center for Innovation and Outcomes Research, Columbia University Irving Medical Ce…
  • Department of Radiology, NewYork-Presbyterian Hospital, Columbia University Irving Medical Center, New York, NY.
  • Division of Cardiothoracic and Vascular Surgery, NewYork-Presbyterian Hospital, Columbia University Irving Medical Center, New York, NY. Electronic address: ht2225@cumc.columbia.edu.

Förderung

  • May and Samuel Rudin Family Foundation

Zitieren

APA

Chung, M. M., Yu, A., Zhao, Y., Wist, E., Hohri, Y., Kurlansky, P., Leb, J., O'Donnell, T. F. X., Patel, V., & Takayama, H. (2025). Utility of structured follow-up imaging after aortic surgery. The Journal of Thoracic and Cardiovascular Surgery, 169(2), 584-594.e5. https://doi.org/10.1016/j.jtcvs.2024.02.007

Vancouver

Chung MM, Yu A, Zhao Y, Wist E, Hohri Y, Kurlansky P, et al. Utility of structured follow-up imaging after aortic surgery. The Journal of Thoracic and Cardiovascular Surgery. 2025;169(2):584-594.e5. doi:10.1016/j.jtcvs.2024.02.007

BibTeX
@article{Chung2025,
  author = {Chung, Megan M and Yu, Annie and Zhao, Yanling and Wist, Elizabeth and Hohri, Yu and Kurlansky, Paul and Leb, Jay and O'Donnell, Thomas F X and Patel, Virendra and Takayama, Hiroo},
  title = {Utility of structured follow-up imaging after aortic surgery},
  journal = {The Journal of Thoracic and Cardiovascular Surgery},
  year = {2025},
  volume = {169},
  number = {2},
  pages = {584--594.e5},
  doi = {10.1016/j.jtcvs.2024.02.007}
}
Kostenlos starten →