Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2024-01. Verfasst von Daichi Takagi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Akita University Graduate School of Medicine, Akita, Japan. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Aortic Dissection. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To investigate the optimal stent length and distal positioning of frozen elephant trunks (FETs) in patients with type A acute aortic dissection (TAAD). METHODS: Between October 2014 and April 2021, 191 patients (FET-150 group: 37 patients; stent length, 150 mm; 66.3 ± 12.6 years and FET-non-150 group: 154 patients; 60, 90, or 120 mm; 64.1 ± 12.5 years) underwent total arch repair with FETs for TAAD using the "zone 0 arch repair" strategy. In the FET-150 group, the proximal stent end was positioned at the innominate artery origin of the arch. In the FET-non-150 group, the distal stent end was to be positioned just proximal to the aortic valve level using transesophageal echocardiography. The proximal end of the non-stented FET part was sutured to an arch graft together with the aortic wall at 1 to 2 cm proximal to the innominate artery origin. RESULTS: Distal stent ends were positioned at the thoracic vertebrae (Th) 4-5, 6-7, 8-9, and 10 levels in 0 (0%), 12 (32.4%), 25 (67.6%), and 0 (0%) patients, respectively, in the FET-150 group, and in 6 (3.9%), 98 (63.6%), 49 (31.8%), and 1 (0.7%), respectively, in the FET-non-150 group. No between-group difference in postoperative mortality was noted. The incidence of postoperative residual distal malperfusion and new-onset spinal cord ischemia in the FET-150 versus FET-non-150 groups were 2.7% versus 6.5% (P = .62) and 0% versus 1.9% (P = 1.00), respectively. CONCLUSIONS: FET positioning with the distal stent end at around Th 8 can reduce residual distal malperfusion when a FET with a 150-mm stent is deployed from the aortic zone 0 in patients with TAAD undergoing total arch repair.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, ThoracicBlood Vessel Prosthesis ImplantationAortic DissectionHumansRetrospective StudiesStentsAorta, ThoracicBlood Vessel ProsthesisTreatment OutcomeAzidesDeoxyglucose

Stichwörter der Autor:innen

FET positioningdistal stent endoptimal stent lengthresidual distal malperfusiontype A acute aortic dissection

Substanzen

1,3,4,6-tetra-O-acetyl-2-azido-2-deoxyglucopyranoseAzidesDeoxyglucose

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Akita University Graduate School of Medicine, Akita, Japan.
  • Department of Cardiovascular Surgery, Akita University Graduate School of Medicine, Akita, Japan. Electronic address: h-yama@cvs.med.akita-u.ac.jp.

Zitieren

APA

Takagi, D., Yamamoto, H., Kadohama, T., Kiryu, K., Wada, T., & Igarashi, I. (2024). Optimal stent length and distal positioning of frozen elephant trunks deployed from the aortic zone 0 for type A acute aortic dissection. The Journal of Thoracic and Cardiovascular Surgery, 167(1), 15-25.e2. https://doi.org/10.1016/j.jtcvs.2022.03.007

Vancouver

Takagi D, Yamamoto H, Kadohama T, Kiryu K, Wada T, Igarashi I. Optimal stent length and distal positioning of frozen elephant trunks deployed from the aortic zone 0 for type A acute aortic dissection. The Journal of Thoracic and Cardiovascular Surgery. 2024;167(1):15-25.e2. doi:10.1016/j.jtcvs.2022.03.007

BibTeX
@article{Takagi2024,
  author = {Takagi, Daichi and Yamamoto, Hiroshi and Kadohama, Takayuki and Kiryu, Kentaro and Wada, Takuya and Igarashi, Itaru},
  title = {Optimal stent length and distal positioning of frozen elephant trunks deployed from the aortic zone 0 for type A acute aortic dissection},
  journal = {The Journal of Thoracic and Cardiovascular Surgery},
  year = {2024},
  volume = {167},
  number = {1},
  pages = {15--25.e2},
  doi = {10.1016/j.jtcvs.2022.03.007}
}
Kostenlos starten →