EUVIMEDEUVIMED entdecken
Open Access

Under Pressure: Rapid Infusion of Stored Whole Blood Alters Coagulation Parameters

Ellen R Becker, Ryan C Chae, Adam D Price, Lindsey J Wattley, Rebecca M Schuster, Michael D Goodman, Timothy A Pritts

Journal of Surgical Research · 2025-11 · 315 · 381-389

DOI: 10.1016/j.jss.2025.07.067 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Surgical Research, 2025-11. Verfasst von Ellen R Becker und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University of Cincinnati, Cincinnati, Ohio. Hauptthemen laut MEDLINE: Blood Coagulation, Blood Preservation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, National Institutes of Health, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The use of normothermic rapid transfusers to deliver high volumes of warmed blood products to hemorrhaging patients is common practice. However, the effects of these transfusers on the coagulation profile of stored compared to fresh whole blood has not been studied. METHODS: Units of fresh whole blood and blood stored for 21 days were acquired from our local blood bank. Rapid infusion was simulated using a Level 1 H-1200 at 42°C and 300 mmHg of pressure. Samples were taken preinfusion and postinfusion and examined for cell counts, biochemical changes, viability, viscoelastic properties, and microvesicle concentrations. RESULTS: Fresh whole blood was unaffected by rapid infusion in all end points. In contrast, rapid infusion of stored whole blood resulted in significantly higher levels of free hemoglobin (63 ± 25 mg/mL preinfusion to 101 ± 41 mg/mL postinfusion, P = 0.0025), decreased platelet contribution to clot (73 ± 5% to 66 ± 6%, P = 0.0075), decreased platelet aggregation (10.1 ± 5.5 to 6.0 ± 3.7 area under the curve with arachidonic acid, P = 0.03), and increased platelet derived microvesicles (164 ± 151 to 260 ± 163 events/μL, P = 0.01). Platelet and platelet microvesicle concentrations expressing CD62 in stored whole blood remained unchanged postinfusion (P > 0.05). CONCLUSIONS: Infusion of stored whole blood via a rapid infuser resulted in hemolysis, platelet dysfunction, and increased platelet-derived microvesicles. We suspect that platelet destruction due to pressurized infusion leads to an increase in microvesicle concentration and a subsequently altered coagulation profile.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood CoagulationBlood PreservationHumansPlatelet AggregationPressure

Stichwörter der Autor:innen

MicrovesiclesNormothermic rapid transfusionPlatelet dysfunction

Autor:innen und Institutionen

  • Department of Surgery, University of Cincinnati, Cincinnati, Ohio.
  • Department of Surgery, University of Cincinnati, Cincinnati, Ohio. Electronic address: prittsta@ucmail.uc.edu.

Förderung

  • NIGMS NIH HHS
  • National Institutes of Health
  • National Institute of General Medical Sciences

Zitieren

APA

Becker, E. R., Chae, R. C., Price, A. D., Wattley, L. J., Schuster, R. M., Goodman, M. D., & Pritts, T. A. (2025). Under Pressure: Rapid Infusion of Stored Whole Blood Alters Coagulation Parameters. Journal of Surgical Research, 315, 381-389. https://doi.org/10.1016/j.jss.2025.07.067

Vancouver

Becker ER, Chae RC, Price AD, Wattley LJ, Schuster RM, Goodman MD, et al. Under Pressure: Rapid Infusion of Stored Whole Blood Alters Coagulation Parameters. Journal of Surgical Research. 2025;315:381-389. doi:10.1016/j.jss.2025.07.067

BibTeX
@article{Becker2025,
  author = {Becker, Ellen R and Chae, Ryan C and Price, Adam D and Wattley, Lindsey J and Schuster, Rebecca M and Goodman, Michael D and Pritts, Timothy A},
  title = {Under Pressure: Rapid Infusion of Stored Whole Blood Alters Coagulation Parameters},
  journal = {Journal of Surgical Research},
  year = {2025},
  volume = {315},
  pages = {381--389},
  doi = {10.1016/j.jss.2025.07.067}
}
Kostenlos starten →