EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Luminal Delivery of Pectin-Modified Oxygen Microbubbles Mitigates Rodent Experimental Intestinal Ischemia

Mathew Morreau, Ernest Cheah, Sachin Thakur, Jiwon Hong, Anthony Hickey, Anthony Phillips, John Windsor

Journal of Surgical Research · 2024

DOI: 10.1016/j.jss.2024.01.035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Surgical Research, 2024. Verfasst von Mathew Morreau und 6 weiteren Autor:innen. Beteiligte Einrichtung: Surgical and Translational Research Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand. Electronic address…. Hauptthemen laut MEDLINE: Reperfusion Injury, Mesenteric Ischemia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Auckland Medical Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Ischemic gut injury is common in the intensive care unit, impairs gut barrier function, and contributes to multiorgan dysfunction. One novel intervention to mitigate ischemic gut injury is the direct luminal delivery of oxygen microbubbles (OMB). Formulations of OMB can be modified to control the rate of oxygen delivery. This project examined whether luminal delivery of pectin-modified OMB (OMBp5) can reduce ischemic gut injury in a rodent model. METHODS: The OMBp5 formulation was adapted to improve delivery of oxygen along the length of small intestine. Adult Sprague-Dawley rats (n = 24) were randomly allocated to three groups: sham-surgery (SS), intestinal ischemia (II), and intestinal ischemia plus luminal delivery of OMBp5 (II + O). Ischemia-reperfusion injury was induced by superior mesenteric artery occlusion for 45 min followed by reperfusion for 30 min. Outcome data included macroscopic score of mucosal injury, the histological score of gut injury, and plasma biomarkers of intestinal injury. RESULTS: Macroscopic, microscopic data, and intestinal injury biomarker results demonstrated minimal intestinal damage in the SS group and constant damage in the II group. II + O group had a significantly improved macroscopic score throughout the gut mucosa (P = 0.04) than the II. The mean histological score of gut injury for the II + O group was significantly improved on the II group (P ≤ 0.01) in the proximal intestine only, within 30 cm of delivery. No differences were observed in plasma biomarkers of intestinal injury following OMBp5 treatment. CONCLUSIONS: This proof-of-concept study has demonstrated that luminal OMBp5 decreases ischemic injury to the proximal small intestine. There is a need to improve oxygen delivery over the full length of the intestine. These findings support further studies with clinically relevant end points, such as systemic inflammation and vital organ dysfunction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Reperfusion InjuryMesenteric IschemiaRatsAnimalsRats, Sprague-DawleyRodentiaPectinsMicrobubblesIschemiaBiomarkersIntestinal MucosaIntestines

Stichwörter der Autor:innen

Acute and critical illnessIntestinal ischemiaOxygen microbubbles

Substanzen

PectinsBiomarkers

Autor:innen und Institutionen

  • Surgical and Translational Research Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand. Electronic address: mmorreau@xtra.co.nz.
  • School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.
  • Surgical and Translational Research Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand; Applied Surgery and Metabolism Laboratory, School of Biological Science, Faculty of Scie…
  • Surgical and Translational Research Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand; HBP/Upper GI Unit, Department of General Surgery, Auckland City Hospital, Te Whatu Ora T…

Förderung

  • Auckland Medical Research Foundation

Zitieren

APA

Morreau, M., Cheah, E., Thakur, S., Hong, J., Hickey, A., Phillips, A., & Windsor, J. (2024). Luminal Delivery of Pectin-Modified Oxygen Microbubbles Mitigates Rodent Experimental Intestinal Ischemia. Journal of Surgical Research. https://doi.org/10.1016/j.jss.2024.01.035

Vancouver

Morreau M, Cheah E, Thakur S, Hong J, Hickey A, Phillips A, et al. Luminal Delivery of Pectin-Modified Oxygen Microbubbles Mitigates Rodent Experimental Intestinal Ischemia. Journal of Surgical Research. 2024. doi:10.1016/j.jss.2024.01.035

BibTeX
@article{Morreau2024,
  author = {Morreau, Mathew and Cheah, Ernest and Thakur, Sachin and Hong, Jiwon and Hickey, Anthony and Phillips, Anthony and Windsor, John},
  title = {Luminal Delivery of Pectin-Modified Oxygen Microbubbles Mitigates Rodent Experimental Intestinal Ischemia},
  journal = {Journal of Surgical Research},
  year = {2024},
  doi = {10.1016/j.jss.2024.01.035}
}
Kostenlos starten →