EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

What makes a safety control “enough” for high-energy hazards? Defining and testing acceptable alternative controls when a Direct Control is not feasible

Yaqoob Raheemy, Fred Sherratt, Matthew R Hallowell

Journal of Safety Research · 2026-09 · 98 · 376-389

DOI: 10.1016/j.jsr.2026.07.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Safety Research, 2026-09. Verfasst von Yaqoob Raheemy und 2 weiteren Autor:innen. Beteiligte Einrichtung: Construction Safety Research Alliance, University of Colorado Boulder, CO 80309, USA. Electronic address: mohammadyaqoob.raheemy@colorado.edu. Hauptthemen laut MEDLINE: Accidents, Occupational, Safety Management, Construction Industry, Occupational Injuries. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Serious injuries and fatalities (SIFs) in construction have remained stubbornly high despite substantial safety efforts. Prior research suggests that these events frequently arise in contexts where controls are absent, ineffective, poorly defined, or inconsistently implemented. Prevention appears to depend less on adding more controls and more on designing controls that are explicitly intended for SIF prevention, usable in the field, and precise enough to support consistent decisions at the point of risk. Within the energy-based safety framework, the concept of Direct Control has been introduced as a scientifically defined type of control for high-energy hazards with SIF potential. However, Direct Controls are not always feasible, leaving a recurring gap in practice: what constitutes "enough" control when high-energy hazards must be managed without a Direct Control? METHOD: This study addresses that gap through a two-phase research process. In Phase 1, an expert panel of 25 construction safety professionals participated in structured brainstorming, focus groups, and a modified Delphi method to develop a definition and criteria for Alternative Controls. The resulting framework specifies three categories and rules to ensure that Alternative Controls are timely, tangible, targeted, and reliably implemented at the point of risk. In Phase 2, a noise experiment with a separate group of 20 practitioners tested the framework's usability. Variability in adequacy decisions decreased by 47%, inter-rater agreement improved from fair to substantial (Fleiss' κ from 0.21-0.32 to 0.61-0.62), and practitioner confidence increased significantly (paired t-test, p < 0.001). RESULTS: Findings indicate that structured criteria for Alternative Controls can reduce decision noise and support more consistent, SIF-focused control decisions when Direct Controls are not feasible.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Accidents, OccupationalSafety ManagementConstruction IndustryOccupational InjuriesHumansDelphi TechniqueFocus Groups

Stichwörter der Autor:innen

Alternative controlsConstruction safetyDirect controlSafety controlsSerious injuries and fatalities

Autor:innen und Institutionen

  • Construction Safety Research Alliance, University of Colorado Boulder, CO 80309, USA. Electronic address: mohammadyaqoob.raheemy@colorado.edu.
  • Construction Safety Research Alliance, University of Colorado Boulder, CO 80309, USA. Electronic address: fred@nemesisv.co.uk.
  • Construction Safety Research Alliance, University of Colorado Boulder, CO 80309, USA. Electronic address: Matthew.Hallowell@colorado.edu.

Zitieren

APA

Raheemy, Y., Sherratt, F., & Hallowell, M. R. (2026). What makes a safety control “enough” for high-energy hazards? Defining and testing acceptable alternative controls when a Direct Control is not feasible. Journal of Safety Research, 98, 376-389. https://doi.org/10.1016/j.jsr.2026.07.013

Vancouver

Raheemy Y, Sherratt F, Hallowell MR. What makes a safety control “enough” for high-energy hazards? Defining and testing acceptable alternative controls when a Direct Control is not feasible. Journal of Safety Research. 2026;98:376-389. doi:10.1016/j.jsr.2026.07.013

BibTeX
@article{Raheemy2026,
  author = {Raheemy, Yaqoob and Sherratt, Fred and Hallowell, Matthew R},
  title = {What makes a safety control “enough” for high-energy hazards? Defining and testing acceptable alternative controls when a Direct Control is not feasible},
  journal = {Journal of Safety Research},
  year = {2026},
  volume = {98},
  pages = {376--389},
  doi = {10.1016/j.jsr.2026.07.013}
}
Kostenlos starten →