EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Proximal humeral bony adaptations with a short uncemented stem for shoulder arthroplasty: a quantitative analysis

Lisa Peduzzi, Thomas Goetzmann, Frank Wein, Olivier Roche, François Sirveaux, Daniel Mole, Adrien Jacquot

JSES Open Access · 2019-12 · 3 (4) · 278-286

DOI: 10.1016/j.jses.2019.09.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JSES Open Access, 2019-12. Verfasst von Lisa Peduzzi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Centre Chirurgical Emile Gallé, Nancy, France. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Short uncemented stems have recently been proposed as an alternative to classic long stems for shoulder arthroplasty. The early results are promising, but bony adaptations of the proximal humerus have been reported. The aim of this study was to quantify these phenomena using the Ascend Flex stem and to determine the risk factors. MATERIALS AND METHODS: In a retrospective, single-center study, 183 shoulder arthroplasties were evaluated at 2-year follow-up. All patients underwent clinical evaluations preoperatively and at last follow-up. Radiographs were obtained preoperatively, postoperatively, and at last follow-up. Four types of bony adaptations were analyzed: medial cortical narrowing (MCN), medial metaphysis thinning (MMT), lateral metaphysis thinning (LMT), and under-the-baseplate osteolysis. The risk factors were analyzed in a multivariate model. RESULTS: MCN was found in 72.6% of cases and was severe (>50%) in 4.4%. MMT was found in 46.4% of cases and was severe in 3.3%. LMT was found in 9.8% of cases and was severe in 2.8%. The risk factors for MCN were the distal filling ratio, osteoporosis, and female sex, whereas MMT and LMT were only influenced by stem axis deviation. Under-the-baseplate osteolysis was found in 34.4% of cases. No influence of bony adaptations on the clinical outcomes was observed. We found no complications related to the stem or to stem loosening. CONCLUSION: The radiographic evolution was satisfactory at mid-term follow-up. Bony adaptations seemed to be limited phenomena, without any observed consequence. Avoiding excessive filling and axis deviation may limit these phenomena.

Schlagwörter

Stichwörter der Autor:innen

Shoulder arthroplastybony adaptationsosteolysisshort stemstress shieldinguncemented stem

Autor:innen und Institutionen

  • Centre Chirurgical Emile Gallé, Nancy, France.
  • Centre ARTICS, Chirurgie des Articulations et du Sport, Nancy, France.
  • SAS Pasteur, Clinique Louis Pasteur, Essey-lès-Nancy, France.

Zitieren

APA

Peduzzi, L., Goetzmann, T., Wein, F., Roche, O., Sirveaux, F., Mole, D., & Jacquot, A. (2019). Proximal humeral bony adaptations with a short uncemented stem for shoulder arthroplasty: a quantitative analysis. JSES Open Access, 3(4), 278-286. https://doi.org/10.1016/j.jses.2019.09.011

Vancouver

Peduzzi L, Goetzmann T, Wein F, Roche O, Sirveaux F, Mole D, et al. Proximal humeral bony adaptations with a short uncemented stem for shoulder arthroplasty: a quantitative analysis. JSES Open Access. 2019;3(4):278-286. doi:10.1016/j.jses.2019.09.011

BibTeX
@article{Peduzzi2019,
  author = {Peduzzi, Lisa and Goetzmann, Thomas and Wein, Frank and Roche, Olivier and Sirveaux, François and Mole, Daniel and Jacquot, Adrien},
  title = {Proximal humeral bony adaptations with a short uncemented stem for shoulder arthroplasty: a quantitative analysis},
  journal = {JSES Open Access},
  year = {2019},
  volume = {3},
  number = {4},
  pages = {278--286},
  doi = {10.1016/j.jses.2019.09.011}
}