Risk factors associated with blood transfusion after shoulder arthroplasty
JSES Open Access · 2017
DOI: 10.1016/j.jses.2017.03.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift JSES Open Access, 2017. Verfasst von Eric C Makhni und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, New York Presbyterian, Columbia University Medical Center, New York, NY, USA. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Closed-suction drainage has been studied extensively in hip and knee arthroplasty literature. However, little is known about outcomes in patients treated with drainage after shoulder arthroplasty, particularly relative to transfusion requirements. METHODS: All primary total and reverse total shoulder arthroplasties (TSAs and RSAs) performed at a single institution during a 5-year period were retrospectively reviewed. Data collected included patient demographic information, estimated blood loss (EBL), drain output, length of drain use, changes in hemoglobin (Hgb) level postoperatively, transfusions, and complications. A multivariable regression analysis was performed to identify independent risk factors for transfusion. RESULTS: There were no differences in surgery duration, EBL, or complications between TSA and RSA patients (P > .05). Patients undergoing RSA were older (74.0 vs. 68.4 years; P < .001) and had lower preoperative and postoperative Hgb levels (P < .001) compared with TSA patients. Reverse arthroplasty was also associated with longer hospital stays (2.8 vs. 2.2 days; P < .001), longer drain durations (1.6 vs. 1.2 days; P < .001), increased total wound drainage (209 vs. 168 m; P = .006), and higher transfusion rates (11.7% vs. 3.1%; P = .002). Independent risk factors for transfusion included low preoperative Hgb levels in both TSA (P = .024) and RSA (P = .002) and higher EBL in TSA (P = .031). CONCLUSION: Low preoperative Hgb level is an independent risk factor for requiring blood transfusion after TSA and RSA. Increased wound drainage was not a risk factor for transfusion, and the 40-mL increase in wound drainage found in RSA is of questionable clinical significance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, New York Presbyterian, Columbia University Medical Center, New York, NY, USA.
Zitieren
APA
Makhni, E. C., Trofa, D. P., Watling, J. P., Bobman, J. T., Bigliani, L. U., Jobin, C. M., Levine, W. N., & Ahmad, C. S. (2017). Risk factors associated with blood transfusion after shoulder arthroplasty. JSES Open Access. https://doi.org/10.1016/j.jses.2017.03.004
Vancouver
Makhni EC, Trofa DP, Watling JP, Bobman JT, Bigliani LU, Jobin CM, et al. Risk factors associated with blood transfusion after shoulder arthroplasty. JSES Open Access. 2017. doi:10.1016/j.jses.2017.03.004
BibTeX
@article{Makhni2017,
author = {Makhni, Eric C and Trofa, David P and Watling, Jonathan P and Bobman, Jacob T and Bigliani, Louis U and Jobin, Charles M and Levine, William N and Ahmad, Christopher S},
title = {Risk factors associated with blood transfusion after shoulder arthroplasty},
journal = {JSES Open Access},
year = {2017},
doi = {10.1016/j.jses.2017.03.004}
}
EUVIMED