EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Biomechanical Evaluation of Primary Stability in Revision Latarjet Surgery Using Malleolar Screws Following Failure of All-Suture Cerclage Fixation

Tobias P Bayer, Anna-Katharina Nolte, Benjamin Panzram, Patric Raiss, Kilian Wegmann, J Philippe Kretzer, Matthias Bülhoff, Sebastian Jaeger

Journal of Shoulder and Elbow Surgery · 2026

DOI: 10.1016/j.jse.2026.02.014 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2026. Verfasst von Tobias P Bayer und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland; Research Center of Biomechanics and Implant Technology, D…. Hauptthemen laut MEDLINE: Bone Screws, Suture Techniques, Joint Instability. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Metal-free fixation methods, such as the all-suture cerclage technique for the Latarjet procedure, aim to minimize implant-related complications. Clinical studies suggest equivalent clinical results while reducing implant-related complications. However, recent studies have shown increased rates of graft migration and failure due to cortical cut-through. Revision strategies after such failures remain poorly described. The aim of this study is to evaluate the primary stability of revision Latarjet surgery using 2 conventional malleolar screws after failure of all-suture cerclage fixation compared with primary screw fixation. It is hypothesized that fixation of the coracoid graft using 2 malleolar screws in revision cases is equal to or higher than primary screw fixation. METHODS: Twelve fresh-frozen cadaveric shoulder specimens (6 matched pairs) were previously tested in a study comparing suture cerclage and malleolar screw fixation. After failure due to cortical bone cut-through, revision surgery was performed on the cerclage specimens using 2 malleolar screws. Bone graft displacement under cyclic loading in 6 load levels (up to 300 N) and static conjoint tendon tension (10 N) was measured using a 3-dimensional optical marker system. Outcomes were compared with those from primary screw fixations. RESULTS: No statistically significant differences in graft displacement under cyclic loading between the revision and primary groups at any load level (P > .05) could be found. The revision group showed slightly higher displacement at low load levels but demonstrated superior stability at higher loads compared with primary screw fixation. One intraoperative graft fracture was observed during revision, but it did not affect the primary stability of the tested specimen. CONCLUSION: Revision Latarjet surgery using malleolar screw fixation after failed all-suture cerclage provides noninferior biomechanical primary stability compared with primary screw fixation. This technique appears to be a viable salvage option for addressing instability after failure of metal-free Latarjet constructs. Clinical studies need to be conducted in order to confirm the results of this biomechanical study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone ScrewsSuture TechniquesJoint InstabilityHumansReoperationCadaverBiomechanical PhenomenaFemaleMaleAgedMiddle Aged

Stichwörter der Autor:innen

Latarjetbiomechanicalmetal-free Latarjetprimary graft stabilityrevisionsuture cerclage

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland; Research Center of Biomechanics and Implant Technology, Department of Orthopaedics, Heidelberg University Hospital, Heidelberg,…
  • Research Center of Biomechanics and Implant Technology, Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany; Department of Traumatology, Hand Surgery and Sports Medicine, ViDia Clinics Karlsr…
  • Research Center of Biomechanics and Implant Technology, Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany; Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany.
  • Medical Faculty, Heidelberg University Hospital, Heidelberg, Germany; OCM (Orthopaedische Chirurgie Muenchen), Munich, Germany.
  • OCM (Orthopaedische Chirurgie Muenchen), Munich, Germany.

Zitieren

APA

Bayer, T. P., Nolte, A. K., Panzram, B., Raiss, P., Wegmann, K., Kretzer, J. P., Bülhoff, M., & Jaeger, S. (2026). Biomechanical Evaluation of Primary Stability in Revision Latarjet Surgery Using Malleolar Screws Following Failure of All-Suture Cerclage Fixation. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2026.02.014

Vancouver

Bayer TP, Nolte AK, Panzram B, Raiss P, Wegmann K, Kretzer JP, et al. Biomechanical Evaluation of Primary Stability in Revision Latarjet Surgery Using Malleolar Screws Following Failure of All-Suture Cerclage Fixation. Journal of Shoulder and Elbow Surgery. 2026. doi:10.1016/j.jse.2026.02.014

BibTeX
@article{Bayer2026,
  author = {Bayer, Tobias P and Nolte, Anna-Katharina and Panzram, Benjamin and Raiss, Patric and Wegmann, Kilian and Kretzer, J Philippe and Bülhoff, Matthias and Jaeger, Sebastian},
  title = {Biomechanical Evaluation of Primary Stability in Revision Latarjet Surgery Using Malleolar Screws Following Failure of All-Suture Cerclage Fixation},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2026},
  doi = {10.1016/j.jse.2026.02.014}
}
Kostenlos starten →