A low-profile anatomical locking plate for the treatment of humerus split-type greater tuberosity fractures compared to the proximal humerus internal locking system (PHILOS): a retrospective study
Journal of Shoulder and Elbow Surgery · 2026
DOI: 10.1016/j.jse.2025.11.025 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2026. Verfasst von Ning-Jie Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Shaoxing TCM Hospital Affiliated to Zhejiang Chinese Medical University (Shaoxing Hospital of Traditional Chinese Medicin…. Hauptthemen laut MEDLINE: Bone Plates, Shoulder Fractures, Fracture Fixation, Internal. Die Arbeit nennt 33 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Locking plate fixation is an effective treatment for greater tuberosity (GT) fractures. This study aimed to compare the clinical and radiological outcomes between a low-profile anatomical locking plate (LPALP) and the proximal humeral internal locking system (PHILOS) for displaced split-type GT fractures. METHODS: Between May 2017 and October 2023, 43 patients, followed for at least 12 months, with split-type GT fractures fixed with a PHILOS or LPALP were included. In this retrospective study, we compared the clinical and radiological outcomes of the 2 groups, assessed using operation time, incision size, blood loss, implant cost, duration of hospital stay, the Disabilities of the Arm, Shoulder and Hand (DASH) score, Constant-Murley (CM) score, visual analogue scale (VAS), 'GT to head height,' secondary displacement of the GT, secondary operation, complications, and patient satisfaction with cosmetic appearance. RESULTS: There were 18 patients in the PHILOS group and 25 patients in the LPALP group. Implantation of the PHILOS required a significantly longer operation time (82.4 ± 8.3 vs. 54.5 ± 7.9 min, P < .001), larger incision (9.1 ± 0.6 vs. 5.1 ± 0.4 cm, P < .001), and longer duration of hospital stay (8.2 ± 1.7 vs. 7.0 ± 1.3 days, P = .016) than the LPALP. The PHILOS implant also cost significantly more (15,950 ± 630.8 vs. 13,460 ± 346.4 yuan, P < .001) and involved greater blood loss (102.8 ± 10.9 vs. 52.8 ± 9.8 mL, P < .001) than the LPALP. No significant difference was observed between the 2 groups with respect to the 'GT to head height,' bone union time, secondary displacement of the GT, VAS scores, or incidence of complications. The CM score (91.1 ± 6.8 vs. 83.6 ± 11.3 points, P = .010) and DASH score (7.8 ± 5.0 vs. 13.6 ± 10.0 points, P = .024) were both significantly better in the LPALP group compared with the PHILOS group. In addition, patients in the LPALP group were more satisfied with the cosmetic appearance (92.0% vs. 55.6%, P = .009) and required a lower rate of secondary operation (0.0% vs. 22.2%, P = .024) than the PHILOS group. CONCLUSIONS: LPALP fixation for displaced split-type GT fractures was associated with a shorter surgical time, smaller incision, reduced blood loss, lower implant costs, better cosmetic and functional outcomes, and a lower reoperation rate compared with PHILOS fixation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Shaoxing TCM Hospital Affiliated to Zhejiang Chinese Medical University (Shaoxing Hospital of Traditional Chinese Medicine), Shaoxing, Zhejiang, China.
- Department of Orthopaedics, Shanghai Sixth People's Hospital, Shanghai, China; National Center for Orthopaedics, Shanghai Sixth People's Hospital, Shanghai, China.
- Department of Orthopaedics, Zhuhai People's Hospital (The Affiliated Hospital of Beijing Institute of Technology, Zhuhai Clinical Medical College of Jinan University), Zhuhai, Guangdong, China.
- Department of Orthopaedics, Shanghai Sixth People's Hospital, Shanghai, China; National Center for Orthopaedics, Shanghai Sixth People's Hospital, Shanghai, China. Electronic address: drhenyunfeng@sina.com.
- Department of Orthopaedics, Zhuhai People's Hospital (The Affiliated Hospital of Beijing Institute of Technology, Zhuhai Clinical Medical College of Jinan University), Zhuhai, Guangdong, China. Electronic address: zengl…
Zitieren
APA
Zhang, N. J., Chai, Y. J., Jiang, Y. W., He, J. M., Chen, Y. F., & Zeng, L. Q. (2026). A low-profile anatomical locking plate for the treatment of humerus split-type greater tuberosity fractures compared to the proximal humerus internal locking system (PHILOS): a retrospective study. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2025.11.025
Vancouver
Zhang NJ, Chai YJ, Jiang YW, He JM, Chen YF, Zeng LQ. A low-profile anatomical locking plate for the treatment of humerus split-type greater tuberosity fractures compared to the proximal humerus internal locking system (PHILOS): a retrospective study. Journal of Shoulder and Elbow Surgery. 2026. doi:10.1016/j.jse.2025.11.025
BibTeX
@article{Zhang2026,
author = {Zhang, Ning-Jie and Chai, Yi-Jie and Jiang, Yu-Wen and He, Jian-Ming and Chen, Yun-Feng and Zeng, Lang-Qing},
title = {A low-profile anatomical locking plate for the treatment of humerus split-type greater tuberosity fractures compared to the proximal humerus internal locking system (PHILOS): a retrospective study},
journal = {Journal of Shoulder and Elbow Surgery},
year = {2026},
doi = {10.1016/j.jse.2025.11.025}
}