EUVIMEDEUVIMED entdecken
Crossref

Characterizing glenoid wear after hemiarthroplasty with concentric glenoid reaming: a study of 113 arthroplasties at a mean of 6.7 years of follow-up

Andrew P Collins, Mihir M Sheth, James F Stenson, Ermyas A Kahsai, Kevin J Khoo, Temi Ogunleye, Anastasia J Whitson, Frederick A Matsen, Jason E Hsu

Journal of Shoulder and Elbow Surgery · 2025

DOI: 10.1016/j.jse.2025.08.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Andrew P Collins und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery and Sports Medicine, University of Washington Medical Center, Seattle, WA, USA. Hauptthemen laut MEDLINE: Hemiarthroplasty, Shoulder Joint, Arthroplasty, Replacement, Shoulder, Glenoid Cavity. Die Arbeit nennt 21 Literaturangaben. Gefördert von: National Center for Advancing Translational Sciences, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Hemiarthroplasty with concentric glenoid reaming (ream-and-run arthroplasty) using a metal humeral head can be considered in young, active patients who want to remain active and avoid the risks and limitations associated with a prosthetic glenoid component. However, there are concerns with glenoid bone wear over time. This study sought to better characterize the amount and rate of glenoid wear and associations with glenoid wear with patient-reported outcomes. MATERIALS AND METHODS: Patients enrolled into shoulder arthroplasty database with comparable radiographs and minimum 4-year radiographic follow-up were included. Medialization was determined by measuring the position of the humeral head center of rotation relative to a line drawn through the lateral edge of the acromion and parallel with the glenoid face. The amount of medialization was calculated between interval radiographs. Glenoid wear was categorized into minimal/mild (≤5 mm), moderate (>5 mm but below ≤10 mm), or substantial (>10 mm). Simple Shoulder Test were collected preoperatively and annually for each patient. RESULTS: Comparable radiographs of 113 shoulders with a mean radiographic follow-up of 6.7 ± 2.3 years were analyzed. Minimal/mild glenoid wear was noted in 92 (81%) patients, moderate wear in 15 (13%), and severe wear in 6 (5%). The mean total glenoid wear was 2.9 ± 4.3 mm. Based on linear modeling, the glenoid wear rate was calculated at 0.3 mm per year, but medialization rates were best predicted by a quadratic function (R2 = 0.821; P = .001) rather than a linear function. The majority of glenoid wear occurred in the first 4 years after ream-and-run arthroplasty and plateaued thereafter. On multivariable analysis, younger patients (P = .004) and patients without prior shoulder surgery (P = .015) were at risk for moderate or severe glenoid wear. Change in Simple Shoulder Test and pain scores were not different in those with minimal/mild wear compared to those with moderate or severe medialization, but open revision rates were higher in those with moderate or severe medialization. CONCLUSION: Glenoid wear after hemiarthroplasty with concentric glenoid reaming using a metallic humeral head occurs at a rate of approximately 0.3 mm/year but may not be linear over time. Improvement in clinical outcomes demonstrated no differences between minimal/mild wear and moderate/severe wear cohorts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemiarthroplastyShoulder JointArthroplasty, Replacement, ShoulderGlenoid CavityShoulder ProsthesisHumansMaleFemaleFollow-Up StudiesMiddle AgedAgedRetrospective StudiesRadiographyTime FactorsProsthesis FailureProsthesis DesignOsteoarthritis

Stichwörter der Autor:innen

Shoulder hemiarthroplastyglenoid looseningglenoid wearhumeral head medializationhumeral head replacementream-and-run arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery and Sports Medicine, University of Washington Medical Center, Seattle, WA, USA.
  • Anderson Orthopaedic Clinic, Arlington, VA, USA.
  • Jefferson Einstein Montgomery Medical Center, East Norriton Twp, PA, USA.
  • Department of Orthopaedic Surgery and Sports Medicine, University of Washington Medical Center, Seattle, WA, USA. Electronic address: jehsu@uw.edu.

Förderung

  • National Center for Advancing Translational Sciences
  • National Institutes of Health

Zitieren

APA

Collins, A. P., Sheth, M. M., Stenson, J. F., Kahsai, E. A., Khoo, K. J., Ogunleye, T., Whitson, A. J., Matsen, F. A., & Hsu, J. E. (2025). Characterizing glenoid wear after hemiarthroplasty with concentric glenoid reaming: a study of 113 arthroplasties at a mean of 6.7 years of follow-up. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2025.08.014

Vancouver

Collins AP, Sheth MM, Stenson JF, Kahsai EA, Khoo KJ, Ogunleye T, et al. Characterizing glenoid wear after hemiarthroplasty with concentric glenoid reaming: a study of 113 arthroplasties at a mean of 6.7 years of follow-up. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2025.08.014

BibTeX
@article{Collins2025,
  author = {Collins, Andrew P and Sheth, Mihir M and Stenson, James F and Kahsai, Ermyas A and Khoo, Kevin J and Ogunleye, Temi and Whitson, Anastasia J and Matsen, Frederick A and Hsu, Jason E},
  title = {Characterizing glenoid wear after hemiarthroplasty with concentric glenoid reaming: a study of 113 arthroplasties at a mean of 6.7 years of follow-up},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2025},
  doi = {10.1016/j.jse.2025.08.014}
}
Kostenlos starten →