Comparison of patient-specific instrumentation, navigation, and mixed reality technologies for accurate glenoid positioning in reverse total shoulder arthroplasty: a systematic review and meta-analysis

DongHwan Lee, Jiseung Yoo, Jong Pil Yoon, Kyung-Soo Oh, Seok Won Chung

Journal of Shoulder and Elbow Surgery · 2026

DOI: 10.1016/j.jse.2025.07.019 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2026. Verfasst von DongHwan Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Konkuk University School of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Surgery, Computer-Assisted, Glenoid Cavity, Shoulder Joint. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Konkuk University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The aim of this study was to compare the accuracy of glenoid implant positioning achieved using emerging technologies, including patient-specific instrumentation (PSI), surgical navigation (NAV), and mixed reality (MR) in reverse total shoulder arthroplasty (rTSA). METHODS: A systematic literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, utilizing the PubMed, Scopus, and EMBASE databases to identify English-language original studies. Studies meeting predefined inclusion and exclusion criteria were selected to evaluate glenoid implant positioning in rTSA using PSI, NAV, and MR techniques. A meta-analysis was performed, incorporating both cadaveric and clinical studies, to analyze radiologic outcomes based on deviations from preoperative planning. Radiologic assessments included comparisons of version, inclination, and entry point offset across techniques. The outcomes of glenoid component positioning were analyzed using a random-effects model with the restricted maximum likelihood estimator. RESULTS: Out of 2,794 articles identified, 14 met the inclusion criteria for the systematic review. The analysis included both clinical and cadaveric studies for PSI and NAV techniques. PSI and NAV showed reduced deviations in version and inclination compared to the conventional method (CON). Statistical significance was observed only for inclination between PSI and CON (P = .030), and for both version and inclination between NAV and CON (all P < .001). When comparing PSI and NAV, PSI demonstrated significantly lower deviations in version and inclination (all P < .001). For MR, only cadaveric studies were available for analysis. In comparisons between MR and NAV, MR showed significantly lower deviations in version and inclination (all P < .001). However, when comparing MR and PSI, mixed results were observed: MR had lower deviations in version and inclination, while PSI showed lower deviations in entry point offset (all P < .001). CONCLUSION: Both PSI and NAV methods demonstrated improved accuracy compared to the CON method, with PSI showing superior accuracy and smaller deviations than NAV. While limited to cadaveric studies, MR showed greater accuracy than NAV but produced mixed results when compared to PSI. Further clinical studies on MR are needed to validate and generalize these findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderSurgery, Computer-AssistedGlenoid CavityShoulder JointShoulder ProsthesisSurgical Navigation SystemsHumans

Stichwörter der Autor:innen

Patient-specific instrumentationaccuracyglenoid implant positioningmixed realityreverse total shoulder arthroplastysurgical navigation

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Konkuk University School of Medicine, Seoul, Republic of Korea.
  • Department of Orthopaedic Surgery, Kyungpook National University College of Medicine, Daegu, Republic of Korea.
  • Department of Orthopaedic Surgery, Konkuk University School of Medicine, Seoul, Republic of Korea. Electronic address: smilecsw@gmail.com.

Förderung

  • Konkuk University

Zitieren

APA

Lee, D., Yoo, J., Yoon, J. P., Oh, K. S., & Chung, S. W. (2026). Comparison of patient-specific instrumentation, navigation, and mixed reality technologies for accurate glenoid positioning in reverse total shoulder arthroplasty: a systematic review and meta-analysis. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2025.07.019

Vancouver

Lee D, Yoo J, Yoon JP, Oh KS, Chung SW. Comparison of patient-specific instrumentation, navigation, and mixed reality technologies for accurate glenoid positioning in reverse total shoulder arthroplasty: a systematic review and meta-analysis. Journal of Shoulder and Elbow Surgery. 2026. doi:10.1016/j.jse.2025.07.019

BibTeX
@article{Lee2026,
  author = {Lee, DongHwan and Yoo, Jiseung and Yoon, Jong Pil and Oh, Kyung-Soo and Chung, Seok Won},
  title = {Comparison of patient-specific instrumentation, navigation, and mixed reality technologies for accurate glenoid positioning in reverse total shoulder arthroplasty: a systematic review and meta-analysis},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2026},
  doi = {10.1016/j.jse.2025.07.019}
}
Kostenlos starten →