EUVIMEDEUVIMED entdecken
Fall-Kontroll-Studie

Preoperative “target marking” on the skin reduces radiation exposure and total surgical duration in surgically treated pediatric supracondylar humerus fractures: a case-control clinical study

Yasin Erdoğan, Şahan Güven, Fırat Yaman, Ali Said Nazlıgül, Ali Şahin, Christos Koutserimpas, Enejd Veizi

Journal of Shoulder and Elbow Surgery · 2025-09 · 34 (9) · e793-e799

DOI: 10.1016/j.jse.2024.12.030 ↗

Kurz gefasst

Fall-Kontroll-Studie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025-09. Verfasst von Yasin Erdoğan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Ankara Etlik City Hospital, Ankara, Turkey. Hauptthemen laut MEDLINE: Humeral Fractures, Radiation Exposure, Operative Time, Fracture Fixation, Internal. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Primary treatment for supracondylar humerus fractures (SCHF) involves a closed reduction and fixation with K-wires. The aim of this study is to investigate whether a target marking of the humerus is effective in reducing operation duration and radiation exposure in surgically treated pediatric SCHF. METHODS: Patients treated with a closed reduction and percutaneous pinning for an SCHF between 2019 and 2023 were included. The study data were categorized into 2 groups: group 1 patients underwent closed reduction, followed by outlining the boundaries of the humerus on the skin and subsequent fixation with K-wires (target marking group), whereas group 2 patients underwent closed reduction without outlining (unmarked group). The same K-wire configuration, consisting of 2 lateral and 1 medial crossed pinning, was used. Operation duration and the radiation dose received (in millisieverts) were recorded for each patient and then compared among them. RESULTS: Overall surgical duration was significantly shorter in group 1 (P < .001). A significantly lower radiation dose was required in patients of group 1 to achieve a satisfactory reduction for both fracture types and for the overall patient cohort (P < .001). CONCLUSIONS: Enhancing the 3-dimensional perception of the surgeon in pediatric SCHF treated with closed reduction and percutaneous pinning resulted in a reduction of both the operative duration and the radiation dose. A novel method of "target marking" showed a significant reduction in surgical duration and the amount of radiation exposure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Humeral FracturesRadiation ExposureOperative TimeFracture Fixation, InternalPreoperative CareClosed Fracture ReductionHumansMaleFemaleChildCase-Control StudiesChild, PreschoolBone WiresRadiation DosageRetrospective StudiesBone Nails

Stichwörter der Autor:innen

K-wirePediatric traumaclosed reductionelbow fracturesupracondylar humerus fracturetarget marking

Autor:innen und Institutionen

  • Department of Orthopedics and Traumatology, Ankara Etlik City Hospital, Ankara, Turkey.
  • Department of Orthopedics and Traumatology, Ankara Bilkent City Hospital, Ankara, Turkey.
  • Department of Orthopedics and Traumatology, Antalya City Hospital, Ankara, Turkey.
  • Department of Orthopedics and Traumatology, Ankara Sincan Training Research Hospital, Ankara, Turkey.
  • Department of Orthopedics and Traumatology, "251" Hellenic Air Force General Hospital of Athens, Athens, Greece.
  • Department of Orthopedics and Traumatology, Ankara Bilkent City Hospital, Yıldırım Beyazıt University, School of Medicine, Ankara, Turkey. Electronic address: dr.nad89@hotmail.com.

Zitieren

APA

Erdoğan, Y., Güven, Ş., Yaman, F., Nazlıgül, A. S., Şahin, A., Koutserimpas, C., & Veizi, E. (2025). Preoperative “target marking” on the skin reduces radiation exposure and total surgical duration in surgically treated pediatric supracondylar humerus fractures: a case-control clinical study. Journal of Shoulder and Elbow Surgery, 34(9), e793-e799. https://doi.org/10.1016/j.jse.2024.12.030

Vancouver

Erdoğan Y, Güven Ş, Yaman F, Nazlıgül AS, Şahin A, Koutserimpas C, et al. Preoperative “target marking” on the skin reduces radiation exposure and total surgical duration in surgically treated pediatric supracondylar humerus fractures: a case-control clinical study. Journal of Shoulder and Elbow Surgery. 2025;34(9):e793-e799. doi:10.1016/j.jse.2024.12.030

BibTeX
@article{Erdoan2025,
  author = {Erdoğan, Yasin and Güven, Şahan and Yaman, Fırat and Nazlıgül, Ali Said and Şahin, Ali and Koutserimpas, Christos and Veizi, Enejd},
  title = {Preoperative “target marking” on the skin reduces radiation exposure and total surgical duration in surgically treated pediatric supracondylar humerus fractures: a case-control clinical study},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2025},
  volume = {34},
  number = {9},
  pages = {e793--e799},
  doi = {10.1016/j.jse.2024.12.030}
}
Kostenlos starten →