EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Long-term follow-up study of Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis: minimum 10-year clinical outcomes

Hiroyasu Mizuhara, Taro Kasai, Yasunori Omata, Jun Hirose, Sakae Tanaka, Takumi Matsumoto

Journal of Shoulder and Elbow Surgery · 2025

DOI: 10.1016/j.jse.2024.10.025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Hiroyasu Mizuhara und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan. Hauptthemen laut MEDLINE: Arthritis, Rheumatoid, Arthroplasty, Replacement, Elbow, Elbow Prosthesis, Elbow Joint. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Rheumatoid arthritis (RA) often leads to debilitating damage in the elbow joint, which may require total elbow arthroplasty (TEA). The Kudo TEA is one of the unlinked type prostheses with reportedly favorable outcomes. However, there is limited information available regarding its long-term performance. This retrospective study aimed to evaluate the long-term survivorship and identify risk factors associated with failure of the Kudo type-5 TEA in patients with RA, specifically exceeding 10 years. METHODS: Patients with RA who underwent TEA with the Kudo type-5 prosthesis from 1998 to 2009, with a minimum 10-year follow-up, were included. Failure, defined as revision surgery or radiographic loosening, was assessed using the Kaplan-Meier method. The patients' demographic data, radiographic measurements, range of motion, Mayo Elbow Performance Score (MEPS), and the material of the ulnar component were compared between the elbows with and without failure. Univariate analysis identified factors affecting long-term survivorship. RESULTS: Among 49 elbows in 38 patients with a mean follow-up of 13.4 years, significant improvements in flexion range and MEPS were observed. The failure rate was 39%, occurring in 19 elbows. Among these failures, 13 cases were attributed to issues with the ulnar component, making it the most common cause. The overall survivorship rate of the Kudo type-5 prosthesis at 10 years was 78%, as calculated using the Kaplan-Meier method. Factors associated with a higher failure risk included a shorter duration from RA onset to surgery (17.2 ± 5.8 years vs. 23.3 ± 8.7 years; P = .01), a lower preoperative stability score of MEPS (6.6 ± 4.1 vs. 9.3 ± 1.7; P < .01), larger implant deviation assessed by the implant deviation index (9.3 ± 1.3% vs. 5.4 ± 1.1%; P = .03), and the use of the all-polyethylene ulnar component (79.0% vs. 46.7%; P = .04). CONCLUSION: Although the Kudo type-5 prosthesis demonstrated satisfactory results in patients with RA, failures occurred to some extent over a long-term follow-up period. Careful monitoring should be conducted, particularly in cases with a short duration from RA onset to surgery, preoperative instability, misalignment of the implant, and the use of the all-polyethylene ulnar component.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthritis, RheumatoidArthroplasty, Replacement, ElbowElbow ProsthesisElbow JointJoint ProsthesisHumansMaleFemaleFollow-Up StudiesMiddle AgedRetrospective StudiesAgedProsthesis DesignRange of Motion, ArticularProsthesis FailureTreatment OutcomeTime FactorsAdultReoperationAged, 80 and over

Stichwörter der Autor:innen

Kaplan-Meier survivorship analysisKudo type-5implant alignmentlong-term survivorshiprheumatoid arthritistotal elbow arthroplastyunlinked

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan.
  • Department of Orthopaedic Surgery, Japan Community Health care Organization Tokyo Shinjuku Medical Center, Shinjuku-ku, Tokyo, Japan.
  • Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan. Electronic address: mizuharah-eme@h.u-tokyo.ac.jp.

Zitieren

APA

Mizuhara, H., Kasai, T., Omata, Y., Hirose, J., Tanaka, S., & Matsumoto, T. (2025). Long-term follow-up study of Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis: minimum 10-year clinical outcomes. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2024.10.025

Vancouver

Mizuhara H, Kasai T, Omata Y, Hirose J, Tanaka S, Matsumoto T. Long-term follow-up study of Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis: minimum 10-year clinical outcomes. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2024.10.025

BibTeX
@article{Mizuhara2025,
  author = {Mizuhara, Hiroyasu and Kasai, Taro and Omata, Yasunori and Hirose, Jun and Tanaka, Sakae and Matsumoto, Takumi},
  title = {Long-term follow-up study of Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis: minimum 10-year clinical outcomes},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2025},
  doi = {10.1016/j.jse.2024.10.025}
}
Kostenlos starten →