Humeral stem alignment of curved short stem in reverse shoulder arthroplasty: varus/valgus alignment is not a determinant for clinical outcomes

Yong-Jun Lee, Hsien-Hao Chang, Joon-Ryul Lim, Tae-Hwan Yoon, Yong-Min Chun

Journal of Shoulder and Elbow Surgery · 2025

DOI: 10.1016/j.jse.2024.08.022 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Yong-Jun Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Republi…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Prosthesis, Humerus, Shoulder Joint. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study aimed to investigate the influence of curved short stem alignment within the proximal humerus on the clinical outcomes of reverse shoulder arthroplasty. We hypothesized that the varus/valgus alignment would yield clinical outcomes comparable to those of a neutral alignment. METHODS: We retrospectively reviewed 167 patients who underwent reverse shoulder arthroplasty using the Aequalis Ascend Flex implant between January 2017 and December 2021. The study categorized the patients into 3 groups based on the angle difference between the humeral axis and the stem axis: neutral group (GN, defined as within ±5°), valgus group (GL), and varus group (GR). Functional outcomes were assessed using the visual analog scale pain score, subjective shoulder value, American Shoulder and Elbow Surgeons score, University of California Los Angeles shoulder score, and active range of motion. Routine radiographic evaluations were also conducted to assess the filling ratio and bone resorption. RESULTS: Among 138 patients, 89 were in the GN group, 37 (27%) in the GL group, and 12 (9%) in the GR group. The average degree of varus alignment was 6 (range from 5 to 7°), while the average degree of valgus alignment was -7 (range from -8 to -5°). According to our findings, the clinical outcomes did not exhibit significant differences among the 3 groups. Furthermore, the radiologic outcomes showed no significant differences among the 3 groups. CONCLUSIONS: Compared to neutral alignment, varus or valgus alignment of the humeral stem in reverse shoulder arthroplasty using a curved short stem does not significantly affect clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderShoulder ProsthesisHumerusShoulder JointHumansMaleFemaleRetrospective StudiesAgedMiddle AgedRange of Motion, ArticularProsthesis DesignTreatment Outcome

Stichwörter der Autor:innen

Reverse shoulder arthroplastycurved short stemhumeral stem alignmentrange of motionvalgusvarus

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Department of Orthopedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea. Electronic address: min1201@hanmail.net.

Zitieren

APA

Lee, Y. J., Chang, H. H., Lim, J. R., Yoon, T. H., & Chun, Y. M. (2025). Humeral stem alignment of curved short stem in reverse shoulder arthroplasty: varus/valgus alignment is not a determinant for clinical outcomes. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2024.08.022

Vancouver

Lee YJ, Chang HH, Lim JR, Yoon TH, Chun YM. Humeral stem alignment of curved short stem in reverse shoulder arthroplasty: varus/valgus alignment is not a determinant for clinical outcomes. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2024.08.022

BibTeX
@article{Lee2025,
  author = {Lee, Yong-Jun and Chang, Hsien-Hao and Lim, Joon-Ryul and Yoon, Tae-Hwan and Chun, Yong-Min},
  title = {Humeral stem alignment of curved short stem in reverse shoulder arthroplasty: varus/valgus alignment is not a determinant for clinical outcomes},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2025},
  doi = {10.1016/j.jse.2024.08.022}
}
Kostenlos starten →