EUVIMEDEUVIMED entdecken
Crossref

High delta angle after reverse total shoulder arthroplasty increases stresses of the acromion: biomechanical study of different implant positions

Pascal Schenk, Nikita Sutter, Erasmo Molina, Karl Wieser, Christian Gerber, Elias Bachmann

Journal of Shoulder and Elbow Surgery · 2024

DOI: 10.1016/j.jse.2024.05.034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2024. Verfasst von Pascal Schenk und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland. Electronic address: Pascal.Schenk@spitaluster.ch. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Acromion. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Acromial fractures after reverse total shoulder arthroplasty (RTSA) are a common complication. Nevertheless, only a few studies have identified risk factors for acromial fractures after RTSA. High delta angle (combination of inferiorization and medialization of the center of rotation [COR]) after RTSA was identified as a risk factor in recent studies. The aim of this study was the biomechanical exploration of different delta angles and implant configurations with regard to the acromial stress. METHODS: In a rigid body model of the upper extremity muscle, forces of the deltoid muscle were calculated before and after implanting RTSA in different arm and implant positions. The deltoid muscle was divided into an anterior, middle, and posterior part. Implant positions of the glenoid components were changed in the medialization, lateralization, and inferiorization of the COR as well as lateralization of the humeral component. Further, in a finite element model of the upper extremity, the stresses of the acromion in the same implant design configurations were measured. RESULTS: Differences in acromial stress between different delta angle model configurations were observed. Lateralization (5 and 10 mm) of the glenosphere reduced the maximal acromial stress by 21% (1.5 MPa) and 31% (1.3 MPa), respectively. Inferiorization (5 and 10 mm) of the glenosphere increased the maximal acromial stress by 5% (2.0 MPa) and 15% (2.2 MPa), respectively. Changes in positioning the humeral component was found to have the highest impact in this model configuration. A 10-mm-lateralized humeral component reduced acromial stress by 37% (1.2 MPa), whereas in the 6-mm-medialized configuration, an increase in acromial stress by 83% (3.48 MPa) was observed. There was a high correlation between the delta angle and acromial stress (R2 = 0.967). CONCLUSION: Implant design configuration has an impact on the acromial stress. High delta angles correlate with an increase in acromial stress. Both lateralization of the COR and the humerus decreased the acromial stress in our study. The lateralization of the humerus has the highest impact in influencing acromial stress. Because of contrary results in the current literature, further studies with focus on the acromial stress influenced by different anatomic variants of the shoulder and the acromion are needed before a clinical recommendation can be made.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderAcromionHumansBiomechanical PhenomenaStress, MechanicalFinite Element AnalysisShoulder JointProsthesis DesignShoulder ProsthesisDeltoid Muscle

Stichwörter der Autor:innen

acromial fracturesacromial stresscomputational analysis/simulationfinite elementreverse shoulder arthroplastyscapula spine fractures

Autor:innen und Institutionen

  • Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland. Electronic address: Pascal.Schenk@spitaluster.ch.
  • Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland; Laboratory for Orthopaedic Biomechanics, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland.

Zitieren

APA

Schenk, P., Sutter, N., Molina, E., Wieser, K., Gerber, C., & Bachmann, E. (2024). High delta angle after reverse total shoulder arthroplasty increases stresses of the acromion: biomechanical study of different implant positions. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2024.05.034

Vancouver

Schenk P, Sutter N, Molina E, Wieser K, Gerber C, Bachmann E. High delta angle after reverse total shoulder arthroplasty increases stresses of the acromion: biomechanical study of different implant positions. Journal of Shoulder and Elbow Surgery. 2024. doi:10.1016/j.jse.2024.05.034

BibTeX
@article{Schenk2024,
  author = {Schenk, Pascal and Sutter, Nikita and Molina, Erasmo and Wieser, Karl and Gerber, Christian and Bachmann, Elias},
  title = {High delta angle after reverse total shoulder arthroplasty increases stresses of the acromion: biomechanical study of different implant positions},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2024},
  doi = {10.1016/j.jse.2024.05.034}
}
Kostenlos starten →