EUVIMEDEUVIMED entdecken
Kohortenstudie

Radial head replacement for acute complex elbow instability: a long-term comparative cohort study of 2 implant designs

Blanca Diez Sánchez, Raúl Barco, Samuel A Antuña

Journal of Shoulder and Elbow Surgery · 2023

DOI: 10.1016/j.jse.2023.07.023 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2023. Verfasst von Blanca Diez Sánchez und 2 weiteren Autor:innen. Beteiligte Einrichtung: Upper Limb Unit, Hospital Universitario La Paz, Madrid, Spain. Hauptthemen laut MEDLINE: Elbow Joint, Radius Fractures, Joint Instability. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Radial head fractures not amenable to reconstruction should be treated by radial head replacement (RHR) when there is associated elbow or forearm instability. There are multiple RHR designs with different philosophies, but 2 of the most commonly used implants include the anatomic press-fit radial head system and the loose-fit metallic spacer. There is little information available specifically comparing the long-term clinical and radiographic outcomes of these 2 systems. The objective of this study was to compare the long-term clinical and radiologic outcomes of 2 RHR designs in the context of complex acute elbow instability. MATERIALS AND METHODS: Ninety-five patients with an average age of 54 years (range, 21-87 years) underwent an acute RHR (46 press-fit Acumed anatomic and 49 loose-fit Evolve metallic spacer) and were prospectively followed for an average of 61 months (range, 24-157 months). There were 34 terrible triads; 36 isolated RH fractures with medial, lateral, or longitudinal instability; and 25 RH fractures associated with a proximal ulnar fracture. Clinical outcome and disability were evaluated with the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score, and the Disabilities of the Arm, Shoulder, and Hand (DASH) score. Pain and satisfaction were assessed using a visual analog scale. Radiographic analysis included presence of loosening, bone loss, and overstuffing related to the RHR. RESULTS: Eight patients with an anatomic RHR (2 with overstuffing, 3 for stiffness, and 3 with loose implants) and 1 patient with a spacer (with stiffness) required implant removal. There were no significant differences between spacer RHR and anatomic RHR in arc of motion (120° vs. 113°, P = .14), pain relief (1 vs. 1.7, P = .135), MEPS (94 vs. 88; P = .07), Oxford Elbow Score (42.3 vs. 42.2, P = .4), or DASH score (12.2 vs. 14.4, P = .5). However, patients with a spacer RHR were significantly more satisfied (9 vs. 7.7; P = .004) than those with an anatomic implant. Radiographically, 19 anatomic implants had significant proximal bone loss and 10 showed complete lucent lines around the stem. Lucent lines were common around the spacer RHR. These radiographic changes were not always related to worse clinical outcomes. CONCLUSION: Both the anatomic and spacer RHR designs can provide good clinical long-term outcomes. However, patients with a spacer showed a higher degree of satisfaction and those with an anatomic press-fit RHR had a higher revision rate, with radiographic changes that warrant continued follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elbow JointRadius FracturesJoint InstabilityHumansMiddle AgedElbowCohort StudiesTreatment OutcomePainRange of Motion, ArticularRetrospective Studies

Stichwörter der Autor:innen

Radial head replacementelbow instabilitylucent linesradial head fracturestress shielding

Autor:innen und Institutionen

  • Upper Limb Unit, Hospital Universitario La Paz, Madrid, Spain.
  • Upper Limb Unit, Hospital Universitario La Paz, Madrid, Spain. Electronic address: santuna@asturias.com.

Zitieren

APA

Diez Sánchez, B., Barco, R., & Antuña, S. A. (2023). Radial head replacement for acute complex elbow instability: a long-term comparative cohort study of 2 implant designs. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2023.07.023

Vancouver

Diez Sánchez B, Barco R, Antuña SA. Radial head replacement for acute complex elbow instability: a long-term comparative cohort study of 2 implant designs. Journal of Shoulder and Elbow Surgery. 2023. doi:10.1016/j.jse.2023.07.023

BibTeX
@article{DiezSnchez2023,
  author = {Diez Sánchez, Blanca and Barco, Raúl and Antuña, Samuel A},
  title = {Radial head replacement for acute complex elbow instability: a long-term comparative cohort study of 2 implant designs},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2023},
  doi = {10.1016/j.jse.2023.07.023}
}
Kostenlos starten →