EUVIMEDEUVIMED entdecken
Crossref

Lateralization and distalization shoulder angles do not predict outcomes in reverse shoulder arthroplasty for cuff tear arthropathy

Jan-Philipp Imiolczyk, Tankred Imiolczyk, Adrian Góralczyk, Markus Scheibel, Florian Freislederer

Journal of Shoulder and Elbow Surgery · 2024-01 · 33 (1) · 121-129

DOI: 10.1016/j.jse.2023.05.031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2024-01. Verfasst von Jan-Philipp Imiolczyk und 4 weiteren Autor:innen. Beteiligte Einrichtung: Center for Musculoskeletal Surgery, Charité-Universitaetsmedizin Berlin, Berlin, Germany. Hauptthemen laut MEDLINE: Rotator Cuff Tear Arthropathy, Arthroplasty, Replacement, Shoulder, Shoulder Joint, Shoulder Prosthesis. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: In reverse shoulder arthroplasty (RSA), there are a plethora of measurements regarding implant lateralization and distalization to optimize the center of rotation. Two specific measurements known as the "lateralization shoulder angle" (LSA) and "distalization shoulder angle" (DSA) have been the recent focus of studies to assess their association with RSA and postoperative function. The aim of this study was to evaluate the prognostic clinical value of the LSA and DSA in a large cohort of patients with cuff tear arthropathy (CTA) who were treated with different RSA systems. METHODS: Two local shoulder arthroplasty registries were reviewed for all RSA patients documented to have undergone a radiologic assessment and complete 2-year follow-up examination. The main inclusion criterion was primary RSA in patients with CTA. Patients with either a complete teres minor tear, os acromiale, or acromial stress fracture reported between the time of surgery and the 24-month follow-up were excluded. Five RSA implant systems with 4 neck-shaft angles (NSAs) were assessed. The Constant score, Subjective Shoulder Value, and range of motion at 2 years were correlated with both the LSA and DSA assessed on 6-month anteroposterior radiographs. Linear and parabolic univariable regressions were calculated for both shoulder angles, for each prosthesis system, and for the entire patient cohort. RESULTS: Between May 2006 and November 2019, there were a total of 630 CTA patients who had undergone primary RSA. Of this large cohort of patients, 270 were treated with the Promos Reverse prosthesis system (NSA, 155°); 44, Aequalis Reversed II (NSA, 155°); 62, Lima SMR Reverse (NSA, 150°); 25, Aequalis Ascend Flex (NSA, 145°); and 229, Univers Revers (NSA, 135°). The mean LSA was 78° (standard deviation [SD], 10°; range, 6°-107°), and the mean DSA was 51° (SD, 10°; range, 7°-91°). The average Constant score at 24 months' follow-up was 68.1 points (SD, 13 points; range, 13-96 points). Neither the linear nor parabolic regression calculations for the LSA or DSA revealed significant associations with any of the clinical outcomes. CONCLUSION: Different patients may achieve different clinical outcomes despite having identical LSA and DSA values. There is no association between angular radiographic measurements and 2-year functional outcomes after RSA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rotator Cuff Tear ArthropathyArthroplasty, Replacement, ShoulderShoulder JointShoulder ProsthesisHumansShoulderTreatment OutcomeRuptureRange of Motion, ArticularRetrospective Studies

Stichwörter der Autor:innen

Reverse shoulder arthroplastybiomechanicscuff tear arthropathydistalizationlateralizationneck-shaft angleshoulder angle

Autor:innen und Institutionen

  • Center for Musculoskeletal Surgery, Charité-Universitaetsmedizin Berlin, Berlin, Germany.
  • Department for Mathematics, University of Mannheim, Mannheim, Germany.
  • Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland.
  • Center for Musculoskeletal Surgery, Charité-Universitaetsmedizin Berlin, Berlin, Germany; Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland.
  • Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland. Electronic address: florian.freislederer@kws.ch.

Zitieren

APA

Imiolczyk, J. P., Imiolczyk, T., Góralczyk, A., Scheibel, M., & Freislederer, F. (2024). Lateralization and distalization shoulder angles do not predict outcomes in reverse shoulder arthroplasty for cuff tear arthropathy. Journal of Shoulder and Elbow Surgery, 33(1), 121-129. https://doi.org/10.1016/j.jse.2023.05.031

Vancouver

Imiolczyk JP, Imiolczyk T, Góralczyk A, Scheibel M, Freislederer F. Lateralization and distalization shoulder angles do not predict outcomes in reverse shoulder arthroplasty for cuff tear arthropathy. Journal of Shoulder and Elbow Surgery. 2024;33(1):121-129. doi:10.1016/j.jse.2023.05.031

BibTeX
@article{Imiolczyk2024,
  author = {Imiolczyk, Jan-Philipp and Imiolczyk, Tankred and Góralczyk, Adrian and Scheibel, Markus and Freislederer, Florian},
  title = {Lateralization and distalization shoulder angles do not predict outcomes in reverse shoulder arthroplasty for cuff tear arthropathy},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2024},
  volume = {33},
  number = {1},
  pages = {121--129},
  doi = {10.1016/j.jse.2023.05.031}
}
Kostenlos starten →