Dried blood spot sampling of testosterone microdosing in healthy females
The Journal of Steroid Biochemistry and Molecular Biology · 2024
DOI: 10.1016/j.jsbmb.2024.106496 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Steroid Biochemistry and Molecular Biology, 2024. Verfasst von Reena Desai und 2 weiteren Autor:innen. Beteiligte Einrichtung: Andrology Department, Concord Hospital &, ANZAC Research Institute, University of Sydney, Sydney, NSW 2139, Australia. Hauptthemen laut MEDLINE: Testosterone, Dried Blood Spot Testing. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PCC.
Abstract (Originalsprache)
Capillary dried blood spot (DBS) analysis coupled with multi-analyte steroid liquid chromatography mass spectrometry (LCMS) is attractive for field studies, home-based self-sampling as well as clinical trials by eliminating costly and laborious sample processing involving venipuncture and frozen storage/shipping while providing multiple steroid measurements from a single small sample. We investigated steroid measurements in DBS samples stored for four years at room temperature prior to analysis compared with the original venipuncture serum samples. Healthy women (n=12) provided paired DBS and blood samples over two weeks run-in before seven days treatment with daily transdermal T gel (12.5 mg) and after the end of treatment on days 0, 1, 2, 4, 7 and 14. Compliance with treatment and sampling was high and no adverse effects were reported. Testosterone (T), androstenedione (A4), 17 hydroxyprogesterone (17OHP) and progesterone (P4) were measured in extracted DBS samples as whole blood concentrations with and without adjustment for hematocrit. Using the same LCMS methods, DBS T and A4 measurements had high correlation with minimal bias from prior serum measurements with DBS T displaying the same pattern as serum, with or without hematocrit adjustment. However, serial whole blood measurements of T without hematocrit adjustment provided the best fitting model compared with serum, urine, or hematocrit-adjusted whole blood T measurements. These finding facilitate and simplify DBS methodology for wider field and home-based self-sampling studies of reproductive steroids indicating the need for hematocrit adjustment may be superfluous.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Andrology Department, Concord Hospital &, ANZAC Research Institute, University of Sydney, Sydney, NSW 2139, Australia.
- Andrology Department, Concord Hospital &, ANZAC Research Institute, University of Sydney, Sydney, NSW 2139, Australia. Electronic address: djh@sydney.edu.au.
Förderung
- PCC
Zitieren
APA
Desai, R., Savkovic, S., & Handelsman, D. J. (2024). Dried blood spot sampling of testosterone microdosing in healthy females. The Journal of Steroid Biochemistry and Molecular Biology. https://doi.org/10.1016/j.jsbmb.2024.106496
Vancouver
Desai R, Savkovic S, Handelsman DJ. Dried blood spot sampling of testosterone microdosing in healthy females. The Journal of Steroid Biochemistry and Molecular Biology. 2024. doi:10.1016/j.jsbmb.2024.106496
BibTeX
@article{Desai2024,
author = {Desai, Reena and Savkovic, Sasha and Handelsman, David J},
title = {Dried blood spot sampling of testosterone microdosing in healthy females},
journal = {The Journal of Steroid Biochemistry and Molecular Biology},
year = {2024},
doi = {10.1016/j.jsbmb.2024.106496}
}
EUVIMED