Analytical variation concerning total 25-hydroxyvitamin D measurement, where are we now? A DEQAS review of current assay performance
The Journal of Steroid Biochemistry and Molecular Biology · 2023-07 · 231 · 106328
DOI: 10.1016/j.jsbmb.2023.106328 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift The Journal of Steroid Biochemistry and Molecular Biology, 2023-07. Verfasst von L E Briggs und 2 weiteren Autor:innen. Beteiligte Einrichtung: DEQAS, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London W6 8RF, UK. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Vitamin D. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
The Vitamin D External Quality Assessment Scheme (DEQAS) distributes serum samples globally, on a quarterly basis, to assess participants' performance of specific methods for 25-hydroxyvitamin D (25OHD) and other vitamin D metabolites. In this review an assessment of the state of the art in the performance of 25OHD methods is presented. This assessment is based on an analysis of data submitted by scheme participants for the 2021/22 distribution cycle, which comprised of four distributions each containing five DEQAS samples. These distributions enabled the assessment of performance across a wide concentration range and included samples containing endogenous 25OHD2. Overall analytical performance continues to improve, but there is still significant method variation and bias in some automated methods. These automated methods continue to be challenged in measuring 25OHD at the extremes of the measuring range and in the presence of 25OHD2. LC-MS/MS methods still show superior performance with regards to bias, but are out-performed by some automated methods in terms of assay variability. Through participating in an accuracy based EQA scheme, such as DEQAS, laboratories are able to assess the accuracy of their methods in comparison to a gold standard reference measurement procedure. It is crucial for all laboratories to be aware of the performance and limitations of their 25OHD assays and to educate their users accordingly in order to ensure reliable assessment of vitamin D status.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- DEQAS, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London W6 8RF, UK.
- DEQAS, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London W6 8RF, UK. Electronic address: emma.walker15@nhs.net.
Zitieren
APA
Briggs, L. E., Whitewood, J. K., & Williams, E. L. (2023). Analytical variation concerning total 25-hydroxyvitamin D measurement, where are we now? A DEQAS review of current assay performance. The Journal of Steroid Biochemistry and Molecular Biology, 231, 106328. https://doi.org/10.1016/j.jsbmb.2023.106328
Vancouver
Briggs LE, Whitewood JK, Williams EL. Analytical variation concerning total 25-hydroxyvitamin D measurement, where are we now? A DEQAS review of current assay performance. The Journal of Steroid Biochemistry and Molecular Biology. 2023;231:106328. doi:10.1016/j.jsbmb.2023.106328
BibTeX
@article{Briggs2023,
author = {Briggs, L E and Whitewood, J K and Williams, E L},
title = {Analytical variation concerning total 25-hydroxyvitamin D measurement, where are we now? A DEQAS review of current assay performance},
journal = {The Journal of Steroid Biochemistry and Molecular Biology},
year = {2023},
volume = {231},
pages = {106328},
doi = {10.1016/j.jsbmb.2023.106328}
}
EUVIMED