Specimen-dependent sampling and signal limitations govern the effectiveness of low-magnification super-resolution in Cryo-EM
Journal of Structural Biology · 2026-11 · 108388
DOI: 10.1016/j.jsb.2026.108388 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Structural Biology, 2026-11. Verfasst von Chun-Hsiung Wang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biological Chemistry, Academia Sinica, Taipei, Taiwan.; Academia Sinica Cryo-EM Facility, Academia Sinica, Taipei 11529, Taiwan. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Academia Sinica, National Science and Technology Council.
Abstract (Originalsprache)
Single-particle cryo-EM routinely delivers near-atomic structures; however, optimizing data collection requires a delicate balance among magnification, sampling bandwidth, and particle throughput. Although low-magnification super-resolution imaging can recover information beyond the physical-pixel Nyquist limit, its benefit varies substantially among specimens. This variability suggests that the effectiveness of super-resolution may depend on whether reconstruction is limited by detector sampling bandwidth or by the recoverable particle signal. However, the conditions that distinguish these two regimes remain poorly defined. Here, we systematically compared super-resolution and physical-pixel workflows at two magnifications using apoferritin (APO) and malate synthase G (MSG) as representative specimens with contrasting molecular size, symmetry, and image contrast. At low magnification, APO exhibited sampling-limited behavior, with super-resolution processing reaching 1.72 Å, whereas the Fourier-cropped Bin2 workflow yielded a CryoSPARC-reported value of 2.74 Å, close to the physical-pixel Nyquist limit. In contrast, MSG exhibited predominantly signal-limited behavior under the same conditions, yielding comparable resolutions of 3.05 Å and 3.00 Å for super-resolution and physical-pixel processing, respectively, despite the increased sampling bandwidth. These contrasting responses were further supported by particle-number saturation, per-particle motion correction, and Q-score analyses, which provided complementary evidence for interpreting the observed sampling- and signal-limited behavior. Together, these results provide a practical framework for assessing whether reconstruction quality is predominantly constrained by sampling bandwidth or recoverable particle signal and offer a rational basis for balancing achievable resolution and particle throughput when selecting acquisition strategies.
Autor:innen und Institutionen
- Institute of Biological Chemistry, Academia Sinica, Taipei, Taiwan.; Academia Sinica Cryo-EM Facility, Academia Sinica, Taipei 11529, Taiwan.
- Institute of Biological Chemistry, Academia Sinica, Taipei, Taiwan.
- Institute of Biological Chemistry, Academia Sinica, Taipei, Taiwan.; Academia Sinica Cryo-EM Facility, Academia Sinica, Taipei 11529, Taiwan. Electronic address: kondo@as.edu.tw.
Förderung
- Academia Sinica
- National Science and Technology Council
Zitieren
APA
Wang, C. H., Wu, K. P., & Chang, Y. C. (2026). Specimen-dependent sampling and signal limitations govern the effectiveness of low-magnification super-resolution in Cryo-EM. Journal of Structural Biology, 108388. https://doi.org/10.1016/j.jsb.2026.108388
Vancouver
Wang CH, Wu KP, Chang YC. Specimen-dependent sampling and signal limitations govern the effectiveness of low-magnification super-resolution in Cryo-EM. Journal of Structural Biology. 2026:108388. doi:10.1016/j.jsb.2026.108388
BibTeX
@article{Wang2026,
author = {Wang, Chun-Hsiung and Wu, Kuen-Phon and Chang, Yuan-Chih},
title = {Specimen-dependent sampling and signal limitations govern the effectiveness of low-magnification super-resolution in Cryo-EM},
journal = {Journal of Structural Biology},
year = {2026},
pages = {108388},
doi = {10.1016/j.jsb.2026.108388}
}
EUVIMED