The dangers of predicting ratio standards using multiple regression: A case study using the ratio standard VO2peak (ml·kg−1·min−1)
Journal of Science and Medicine in Sport · 2026-01 · 29 (1) · 85-90
DOI: 10.1016/j.jsams.2025.08.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Science and Medicine in Sport, 2026-01. Verfasst von Alan Michael Nevill und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Education, Health and Wellbeing, University of Wolverhampton, UK. Electronic address: a.m.nevill@wlv.ac.uk. Hauptthemen laut MEDLINE: Oxygen Consumption, Cardiorespiratory Fitness, Exercise Test. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVES: There are numerous examples in the literature where researchers use multiple-regression models to predict ratio standards despite known dangers associated with such methodologies. The solution, to use allometric models, also appears to have been ignored, for example, when predicting cardiorespiratory fitness, using the ratio standard VO2max (ml·kg-1·min-1). DESIGN: Cross-sectional. METHODS: This case-study compares a previously published multiple regression equation to predict VO2peak (ml·kg-1·min-1) that adopted additive predictors of body mass index (kg·m-2) and a 6-minute run/walk test, with an alternative multiplicative allometric model given by VO2peak (l·min-1) = Mk1 · HTk2 · 6WRTk3 · exp(a + b · age + c · age2) · ε, thought to provide a more interpretable model, as well as providing a superior quality-of-fit. RESULTS: The strong association between VO2peak (l·min-1) and body mass also identified the presence of heteroscedasticity, a characteristic in data that can be resolved using allometry. The allometric model explained over 90 % of the variance (R2 = 0.91) compared to less than 60 % (R2 = 0.58) reported by the original study. The allometric model's results also appear more interpretable, with a positive mass exponent similar to that previously reported in the literature M0.66 based on sound physiological grounds. The positive height exponent can also be explained given that taller children have greater lung function. Finally, the age quadratic identified that children's VO2peak peaks during puberty. CONCLUSIONS: This case study provides powerful evidence that allometric models are more interpretable and provide a superior fit compared with multiple regression models when predicting ratio standards. Note that a simple algebraic adjustment enables researchers to predict the ratio standard VO2peak (ml·kg-1·min-1) without further analyses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Education, Health and Wellbeing, University of Wolverhampton, UK. Electronic address: a.m.nevill@wlv.ac.uk.
- Graduation Program in Human Movement Sciences, Federal University of Rio Grande do Sul, Brazil; Graduation Program in Health Promotion, University of Santa Cruz do Sul, Brazil.
- Graduation Program in Human Movement Sciences, Federal University of Rio Grande do Sul, Brazil.
- Graduation Program in Health Promotion, University of Santa Cruz do Sul, Brazil. Electronic address: cezanereuter@unisc.br.
- Production and Transportation Engineering Department, Federal University of Rio Grande do Sul, Brazil.
- Research Center in Sports Sciences, Health Sciences and Human Development (CIDESD), University of Maia (UMaia), Portugal.
Zitieren
APA
Nevill, A. M., de Castro Silveira, J. F., Gaya, A. R., Reuter, C. P., Del Corona Lorenzi, T., Silva, G., & Bergmann, G. G. (2026). The dangers of predicting ratio standards using multiple regression: A case study using the ratio standard VO2peak (ml·kg−1·min−1). Journal of Science and Medicine in Sport, 29(1), 85-90. https://doi.org/10.1016/j.jsams.2025.08.002
Vancouver
Nevill AM, de Castro Silveira JF, Gaya AR, Reuter CP, Del Corona Lorenzi T, Silva G, et al. The dangers of predicting ratio standards using multiple regression: A case study using the ratio standard VO2peak (ml·kg−1·min−1). Journal of Science and Medicine in Sport. 2026;29(1):85-90. doi:10.1016/j.jsams.2025.08.002
BibTeX
@article{Nevill2026,
author = {Nevill, Alan Michael and de Castro Silveira, João Francisco and Gaya, Anelise Reis and Reuter, Cézane Priscila and Del Corona Lorenzi, Thiago and Silva, Gustavo and Bergmann, Gabriel Gustavo},
title = {The dangers of predicting ratio standards using multiple regression: A case study using the ratio standard VO2peak (ml·kg−1·min−1)},
journal = {Journal of Science and Medicine in Sport},
year = {2026},
volume = {29},
number = {1},
pages = {85--90},
doi = {10.1016/j.jsams.2025.08.002}
}
EUVIMED