Fachartikel in der Zeitschrift JPRAS Open, 2026-11. Verfasst von Iulia Marinescu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, St. Vincent's University Hospital, Dublin, Ireland. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health Service Executive.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The precise and safe preparation of internal mammary vessels (IMVs) is a critical step in microvascular autologous breast reconstruction. These vessels lie within a confined, dynamic space, requiring refined dexterity and careful tissue handling. Opportunities for structured training remain limited. This study aimed to develop and validate a high-fidelity synthetic model for IMV preparation and assess its educational value. Materials & Methods: A synthetic post-mastectomy chest model was designed in collaboration with specialist technicians with expertise in simulation design and implementation, with iterative input from consultant microsurgeons. Five novice and five expert surgeons participated. Face and content validity were assessed by independent expert evaluation. Construct validity was examined using a task-specific checklist and the Objective Structured Assessment of Technical Skills (OSATS), scored by two blinded assessors. Novice confidence was assessed pre- and post-training.

Results

Expert evaluation demonstrated good face validity, with high ratings for overall realism and anatomical fidelity (4.5/5), vessel dissection (3.25/5) and teaching suitability and utility for higher surgical training (4.25/5). Construct validity was supported by higher expert performance (OSATS: 23.5 vs 18.9; checklist: 10.0 vs 9.4), and faster task completion time (13.8 vs 15.8 min). Inter-rater reliability was moderate to strong (ICC 0.575-0.820). Novice confidence improved significantly following training (mean increase 2.6, t = 6.50, p = 0.003).

Conclusions

This realistically responsive training model demonstrates strong face, content and construct validity. It provides a practical and objective platform for training and assessing internal mammary vessel preparation and supports safer skill acquisition before progression to the operating theatre.

Schlagwörter

Stichwörter der Autor:innen

Breast reconstructionInternal mammary vesselsMicrosurgeryObjective structured assessment of technical skillsSurgical simulationTechnical skills assessment

Autor:innen und Institutionen

  • Department of Plastic and Reconstructive Surgery, St. Vincent's University Hospital, Dublin, Ireland.
  • UCD School of Medicine & Medical Sciences, University College Dublin, Ireland.
  • RCSI SIM Centre for Simulation Education and Research, RCSI University of Medicine and Health Sciences, Dublin, Ireland.
  • Department of Plastic and Reconstructive Surgery, Beaumont Hospital, Dublin, Ireland.
  • Department of Surgery, Division of Plastic, Reconstructive & Aesthetic Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada.
  • Division of Plastic Surgery, UT Health San Antonio, San Antonio, TX, United States.

Förderung

  • Health Service Executive

Zitieren

APA

Marinescu, I., Roche, A. F., O'Conghaile, C., Condron, C., Quidwai, O., Bollard, S., O'Sullivan, B., Smith, J. M., Woods, J., Morrison, C., McArdle, A., Fries, A., & Dolan, R. (2026). A validated high-fidelity synthetic model for internal mammary vessel preparation in autologous breast reconstruction. JPRAS Open, 52, 525-531. https://doi.org/10.1016/j.jpra.2026.09.014

Vancouver

Marinescu I, Roche AF, O'Conghaile C, Condron C, Quidwai O, Bollard S, et al. A validated high-fidelity synthetic model for internal mammary vessel preparation in autologous breast reconstruction. JPRAS Open. 2026;52:525-531. doi:10.1016/j.jpra.2026.09.014

BibTeX
@article{Marinescu2026,
  author = {Marinescu, Iulia and Roche, Adam F and O'Conghaile, Caoimhin and Condron, Claire and Quidwai, Omar and Bollard, Stephanie and O'Sullivan, Barry and Smith, Jamie Martin and Woods, Jack and Morrison, Colin and McArdle, Adrian and Fries, Anton and Dolan, Roisin},
  title = {A validated high-fidelity synthetic model for internal mammary vessel preparation in autologous breast reconstruction},
  journal = {JPRAS Open},
  year = {2026},
  volume = {52},
  pages = {525--531},
  doi = {10.1016/j.jpra.2026.09.014}
}
Kostenlos starten →