Targeted LVA guided by ultra-high frequency ultrasound and ICG lymphography: A pilot study

Caroline Lilja, Jens Ahm Sørensen, Jørn Bo Thomsen

JPRAS Open · 2026-11 · 52 · 288-297

DOI: 10.1016/j.jpra.2026.08.032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JPRAS Open, 2026-11. Verfasst von Caroline Lilja und 2 weiteren Autor:innen. Beteiligte Einrichtung: Research Unit for Plastic Surgery, Odense University Hospital, J. B. Winsløws Vej 4, 5000, Odense C, Region of Southern Denmark, Denmark. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Vissing Fonden, Fabrikant Einar Willumsens Mindelegat, Region Syddanmark.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Breast cancer-related lymphedema (BCRL) is a chronic sequela that significantly impairs quality of life. Lymphovenous anastomosis (LVA) is a promising microsurgical treatment, but its success relies on accurate identification of functional lymphatic vessels and adjacent venules. While indocyanine green lymphography (ICG-L) provides functional lymphatic mapping, venous visualization is often limited. Ultra-high frequency ultrasound (UHFUS), offering high-resolution imaging, may complement ICG-L in preoperative planning. This feasibility study investigated the combined use of ICG-L and UHFUS for vessel identification prior to LVA.

Method

Ten female patients with BCRL were included. Preoperative mapping combined ICG-L for lymphatics and UHFUS (45-70 MHz) for venules before LVA surgery. The primary outcome was agreement between preoperatively identified and intraoperatively confirmed lymphatic and venous vessels, as well as between planned and performed anastomoses. Secondary outcomes included changes in arm volume, quality of life, and L-Dex scores over 12 months.

Results

Preoperative mapping identified a median of two lymphatic and two venous vessels per patient, leading to a median of two planned anastomoses. Intraoperative findings confirmed most vessels, with a median of two anastomoses performed per patient (p = 0.65). Arm volume did not decrease significantly over the 12 months. Quality-of-life and L-Dex scores showed a trend towards improvement.

Conclusion

Combining UHFUS with ICG-L for preoperative planning of LVA is feasible and enables accurate identification of suitable lymphatic and venous vessels. Although no significant reduction in arm volume was observed, improvements in quality of life and L-Dex scores suggest a possible clinical benefit.

Schlagwörter

Stichwörter der Autor:innen

LVALymphedemaMicrosurgerySurgical planningUltra-high frequency ultrasound

Autor:innen und Institutionen

  • Research Unit for Plastic Surgery, Odense University Hospital, J. B. Winsløws Vej 4, 5000, Odense C, Region of Southern Denmark, Denmark.
  • Department of Clinical Research, University of Southern Denmark, Campusvej 55, 5230, Odense M, Region of Southern Denmark, Denmark.
  • The Department of Plastic Surgery, Odense University Hospital, J. B. Winsløws Vej 4, 5000, Odense C, Region of Southern Denmark, Denmark.

Förderung

  • Vissing Fonden
  • Fabrikant Einar Willumsens Mindelegat
  • Region Syddanmark
  • Kræftens Bekæmpelse

Zitieren

APA

Lilja, C., Sørensen, J. A., & Thomsen, J. B. (2026). Targeted LVA guided by ultra-high frequency ultrasound and ICG lymphography: A pilot study. JPRAS Open, 52, 288-297. https://doi.org/10.1016/j.jpra.2026.08.032

Vancouver

Lilja C, Sørensen JA, Thomsen JB. Targeted LVA guided by ultra-high frequency ultrasound and ICG lymphography: A pilot study. JPRAS Open. 2026;52:288-297. doi:10.1016/j.jpra.2026.08.032

BibTeX
@article{Lilja2026,
  author = {Lilja, Caroline and Sørensen, Jens Ahm and Thomsen, Jørn Bo},
  title = {Targeted LVA guided by ultra-high frequency ultrasound and ICG lymphography: A pilot study},
  journal = {JPRAS Open},
  year = {2026},
  volume = {52},
  pages = {288--297},
  doi = {10.1016/j.jpra.2026.08.032}
}