EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Rotation of microtextured anatomical breast implants: A retrospective series of 134 reconstructions

Tarik Ihrai, Alice Roosen, Dominique Lanvin, Philippe Giordano

JPRAS Open · 2026-09 · 51 · 657-663

DOI: 10.1016/j.jpra.2026.07.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JPRAS Open, 2026-09. Verfasst von Tarik Ihrai und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institut du Sein de Mougins, 80 allée des Ormes, 06250, Mougins, France. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Anatomically shaped breast implants are widely used in implant-based breast reconstruction because of their ability to restore breast contour and projection. Following regulatory restrictions on macrotextured implants, microtextured anatomical implants have emerged as an alternative. However, concerns remain regarding their positional stability, particularly the risk of implant rotation.

Methods

We conducted a retrospective review of patients who underwent immediate or delayed implant-based breast reconstruction using microtextured anatomical breast implants between December 2020 and October 2025. All procedures were performed by a single experienced plastic surgeon. Implant rotation and postoperative complications were recorded. Outcomes were analysed on a per-patient basis.

Results

A total of 134 breast reconstructions were performed in 100 patients, with a mean follow-up of 15.5 months. Four cases of implant rotation occurred in four patients, resulting in an overall rotation rate of 4%. Implant rotation was observed exclusively in revision procedures or during second-stage reconstruction. Three cases were successfully managed by external manipulation, and one required surgical revision. Other complication rates were consistent with those reported in the literature.

Conclusion

In this retrospective series, the microtextured anatomical breast implants used in the study, characterized by ultra-low surface roughness, were associated with a low rate of clinically detectable rotation in implant-based breast reconstruction. When combined with meticulous surgical technique and appropriate pocket management, satisfactory positional stability was observed in this cohort.

Schlagwörter

Stichwörter der Autor:innen

Anatomical implantsBreast implantsImplant malrotationImplant-based breast reconstructionMicrotextured surface

Autor:innen und Institutionen

  • Institut du Sein de Mougins, 80 allée des Ormes, 06250, Mougins, France.

Zitieren

APA

Ihrai, T., Roosen, A., Lanvin, D., & Giordano, P. (2026). Rotation of microtextured anatomical breast implants: A retrospective series of 134 reconstructions. JPRAS Open, 51, 657-663. https://doi.org/10.1016/j.jpra.2026.07.014

Vancouver

Ihrai T, Roosen A, Lanvin D, Giordano P. Rotation of microtextured anatomical breast implants: A retrospective series of 134 reconstructions. JPRAS Open. 2026;51:657-663. doi:10.1016/j.jpra.2026.07.014

BibTeX
@article{Ihrai2026,
  author = {Ihrai, Tarik and Roosen, Alice and Lanvin, Dominique and Giordano, Philippe},
  title = {Rotation of microtextured anatomical breast implants: A retrospective series of 134 reconstructions},
  journal = {JPRAS Open},
  year = {2026},
  volume = {51},
  pages = {657--663},
  doi = {10.1016/j.jpra.2026.07.014}
}
Kostenlos starten →