EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Phosphorescence lifetime microscopy and contrast-enhanced ultrasound imaging revealed strong left-to-right intraventricular shunt in anesthetized Xenopus laevis.

Ken Hashimoto, Momoko Ohira, Misaki Kimoto, Akiko Oda, Kosuke Tsukada, Akira Hanashima, Satoshi Mohri

The Journal of Physiological Sciences · 2026-11 · 76 (3) · 100098

DOI: 10.1016/j.jphyss.2026.100098 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Physiological Sciences, 2026-11. Verfasst von Ken Hashimoto und 6 weiteren Autor:innen. Beteiligte Einrichtung: First Department of Physiology, Kawasaki Medical School, Kurashiki 701-0192, Japan. Electronic address: khashimo@med.kawasaki-m.ac.jp. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kawasaki Medical School, Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Amphibians exhibit intracardiac shunting, by which oxygen from multiple respiratory surfaces is variably distributed between systemic and pulmonary circulations. Although shunting has been extensively studied in terrestrial species that rely heavily on pulmonary respiration, much less is known about more aquatic, cutaneous-respiring species, in which cutaneously oxygenated blood returns to the right atrium, so the right-left oxygen gradient should vary with context. Moreover, the proposed role of ventricular trabeculation in limiting intraventricular mixing has not been directly demonstrated. We combined phosphorescence lifetime microscopy for in vivo pO2 measurement with microbubble-based contrast-enhanced ultrasound for high-resolution tracer-tracking in aquatic Xenopus laevis. In anesthetized animals, blood pO2 was uniformly low (25-40 mmHg), with little arteriovenous difference. Right-to-left shunting was minimal (8%), whereas a strong intraventricular left-to-right shunt (47%) maintained threefold greater pulmonary than systemic flow. Although its significance remains to be elucidated, these approaches provide a foundation for advancing shunt research.

Schlagwörter

Stichwörter der Autor:innen

AmphibianContrast-enhanced ultrasoundIntracardiac shuntPhosphorescence lifetime microscopy

Autor:innen und Institutionen

  • First Department of Physiology, Kawasaki Medical School, Kurashiki 701-0192, Japan. Electronic address: khashimo@med.kawasaki-m.ac.jp.
  • First Department of Physiology, Kawasaki Medical School, Kurashiki 701-0192, Japan.
  • Department of Applied Physics and Physico-Informatics, Keio University, Yokohama 223-8522, Japan.

Förderung

  • Kawasaki Medical School
  • Ministry of Education, Culture, Sports, Science and Technology
  • Japan Society for the Promotion of Science

Zitieren

APA

Hashimoto, K., Ohira, M., Kimoto, M., Oda, A., Tsukada, K., Hanashima, A., & Mohri, S. (2026). Phosphorescence lifetime microscopy and contrast-enhanced ultrasound imaging revealed strong left-to-right intraventricular shunt in anesthetized Xenopus laevis. The Journal of Physiological Sciences, 76(3), 100098. https://doi.org/10.1016/j.jphyss.2026.100098

Vancouver

Hashimoto K, Ohira M, Kimoto M, Oda A, Tsukada K, Hanashima A, et al. Phosphorescence lifetime microscopy and contrast-enhanced ultrasound imaging revealed strong left-to-right intraventricular shunt in anesthetized Xenopus laevis. The Journal of Physiological Sciences. 2026;76(3):100098. doi:10.1016/j.jphyss.2026.100098

BibTeX
@article{Hashimoto2026,
  author = {Hashimoto, Ken and Ohira, Momoko and Kimoto, Misaki and Oda, Akiko and Tsukada, Kosuke and Hanashima, Akira and Mohri, Satoshi},
  title = {Phosphorescence lifetime microscopy and contrast-enhanced ultrasound imaging revealed strong left-to-right intraventricular shunt in anesthetized Xenopus laevis},
  journal = {The Journal of Physiological Sciences},
  year = {2026},
  volume = {76},
  number = {3},
  pages = {100098},
  doi = {10.1016/j.jphyss.2026.100098}
}
Kostenlos starten →