EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Hypoxic blackout in dynamic apnea: A case report

Eric Mulder, Isak Löfquist, Felix Schagatay, Arne Sieber, Erika Schagatay

The Journal of Physiological Sciences · 2026

DOI: 10.1016/j.jphyss.2026.100060 ↗

Kurz gefasst

Fallbericht in der Zeitschrift The Journal of Physiological Sciences, 2026. Verfasst von Eric Mulder und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Sciences, Mid Sweden University, Sweden; Swedish Winter Sport Research Centre, Mid Sweden University, Östersund, Sweden. Electro…. Hauptthemen laut MEDLINE: Apnea, Breath Holding, Diving, Hypoxia. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Blackout (BO) in breath-hold diving is attributed to cerebral hypoxia, yet direct observations are rare. We continuously recorded arterial oxygen saturation (SpO₂) and heart rate (HR) in 11 trained freedivers (5 females) performing two dynamic apneas (75 m, 100 m) using a waterproof forehead oximeter. One diver experienced BO at the end of a 100 m dive (SpO₂ 51 %), recovering within 5 s. Group SpO₂ fell from 98 ± 1 % to 77 ± 9 % (75 m) and 68 ± 9 % (100 m; range 51-83 %), while mean HR declined from 83 ± 12 to 43 ± 8 and 40 ± 4bpm, respectively. No arrhythmias were detected. Within-diver SpO₂ nadirs were consistent between distances (r = 0.93), whereas HR nadirs were not (r = 0.40). This case confirms BO can occur at SpO₂ values around 50 %, even in the absence of arrhythmia. The BO diver consistently showed the lowest SpO₂, indicating profound hypoxemia as the most likely contributing factor. Findings support individualized risk screening based on early desaturation patterns in submaximal dives.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ApneaBreath HoldingDivingHypoxiaHumansHeart RateOxygenOxygen Saturation

Stichwörter der Autor:innen

Breath-holdingFreedivingHypoxiaLoss of consciousnessSafety

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Health Sciences, Mid Sweden University, Sweden; Swedish Winter Sport Research Centre, Mid Sweden University, Östersund, Sweden. Electronic address: eric.mulder@miun.se.
  • Swedish Winter Sport Research Centre, Mid Sweden University, Östersund, Sweden.
  • Internal and Acute Medicine, Karolinska University Hospital, Solna, Sweden.
  • Oxygen Scientific GmhB, Graz, Austria.
  • Department of Health Sciences, Mid Sweden University, Sweden; Swedish Winter Sport Research Centre, Mid Sweden University, Östersund, Sweden.

Zitieren

APA

Mulder, E., Löfquist, I., Schagatay, F., Sieber, A., & Schagatay, E. (2026). Hypoxic blackout in dynamic apnea: A case report. The Journal of Physiological Sciences. https://doi.org/10.1016/j.jphyss.2026.100060

Vancouver

Mulder E, Löfquist I, Schagatay F, Sieber A, Schagatay E. Hypoxic blackout in dynamic apnea: A case report. The Journal of Physiological Sciences. 2026. doi:10.1016/j.jphyss.2026.100060

BibTeX
@article{Mulder2026,
  author = {Mulder, Eric and Löfquist, Isak and Schagatay, Felix and Sieber, Arne and Schagatay, Erika},
  title = {Hypoxic blackout in dynamic apnea: A case report},
  journal = {The Journal of Physiological Sciences},
  year = {2026},
  doi = {10.1016/j.jphyss.2026.100060}
}
Kostenlos starten →